STV32 · STV36 · STV40, WSM
(17)Position Light Switch
Position Light Switch
1. Remove the meter panel and disconnect the 6P connector (2)
from position light switch (1) after disconnect the battery
negative code.
2. Remove position light switch (1).
3. Perform the following checking.
(1) Position Light Switch
1) Connector Voltage
1. Connect the battery negative code, then measure the voltage
with a voltmeter across the c terminal and chassis.
2. If the voltage differ from the battery voltage, the wiring harness
is faulty.
Voltage
c terminal - Chassis
(1) 6P Connector
2) Position Light Switch Continuity
1. Measure the resistance with ohmmeter across the a terminal
and c terminal, and across the d terminal and e terminal.
2. If the measurement is not following below, the hazard switch
or the bulb are faulty.
Resistance
a terminal - c terminal
(Switch at OFF)
Resistance
a terminal - c terminal
(Switch at ON)
Resistance (Bulb)
d terminal - e terminal
(1) Position Light Switch
9-S26
ELECTRICAL SYSTEM
(2) 6P Connector
0000007944E
Approx. battery voltage
0000007945E
Infinity
0
Approx. 13
0000007946E
KiSC issued 04, 2006 A