Table 56: Hardware and Device Messages (continued)
Message Code
4116
4117
4118
4119
4120
4121
Message
DSP Board %d cannot set MVIP
reference memory
DSP Board %d fails MVIP RX/TX
ping pong test
DSP node %d - minimum MVIP
RX/TX frame count %d, got %d &
%d
DSP node %d interrupts: Sent %d,
DSP got %d, Host got %d
name %d path error code %d
DSP %d MVIP Ref Memory:
Wrote 0x%d, got 0x%d at 0x%d
Meaning
An attempt to write the reference
memory for the specified DSP
board via the dual-port memory
defining DSo time slots for use by
the transmit PLD on the MVIP bus
failed.
The specified MVIP control test
failed for the specified DSP board.
The specified DSP failed the MVIP
frame count test. The received
counts should have been at least
as much as the specified amount
and be different by no more than
one.
During DSP testing, the host sent
the specified number of interrupts
to the DSP. The number received
by the DSP and the number
received by the host in return are
also specified.
During connectivity testing of the
named path, the error specified by
the two digit code was detected.
The first digit identifies a problem
encountered in the test:
1 - The digits received identify the
wrong channel path.
2 - An unknown event was
received from a DSP.
4 - An unexpected command was
detected in the channel used for
testing.
8 - A DSP required for the test has
failed or is not present.
Any other hexadecimal number
recorded for the first digit is the
sum of the above digits for the
problems indicated. The second
digit indicates the number of
DTMF digits detected over the
specified path. Three digits must
be received that correctly identify
the channel path being tested.
During testing of the specified
DSP, the host wrote the specified
value and read a different value at
the specified memory address.
4 of 6
Issue 1
System Messages
August 2007
289