Table 56: Hardware and Device Messages (continued)
Message Code
4019
4020
4100
4101
4103
4104
4105
4106
Message
Put_(in) active error
Read_intr error
device diagnostic failed
device diagnostic passed
DSP reports error %d on channel
%d
DSP node %d diagnostic failed
Failure detected on DSP node %d
Invalid data (0x%d) for channel
%d
Meaning
An attempt to set a DSP node
active or inactive has failed.
The event process failed to read a
interrupt message from the DSP
driver.
The diagnostic for the specified
device failed.
The diagnostic for the specified
device was completed with no
problems found.
A DSP reported error on the
specified logical channel number.
Recognized errors are:
1 - LLEGAL_COMMAND .set 1.
This command never gets
reported. If an illegal command
is detected, the system ignores
it and goes to the next channel.
2 - RECORD_ERROR .set 2.
The DSP encountered an error
during a record operation.
3 - PLAY_ERROR .set 3.
The DSP encountered an error
during a playback operation.
Possible causes include:
- Non annunciator channel is
asked to play or record.
- Annunciator channel is asked
to play/record when it is
already so doing.
- Annunciator channel tries and
fails to grab a semaphore while
playing/recording.
4 - DTMF_CHAR_ERROR .set 4.
The DSP detected an invalid
character in the digit array.
The diagnostic for the specified
DSP failed.
A process reported that the
specified DSP failed.
The host found that a DSP
contains the indicated invalid
event buffer tail index for the
specified logical channel number.
2 of 6