"expiring" statuses, it plays a prompt requesting that the Leader PIN be updated. The following
table describes the fields and settings related to Leader PIN expiration statuses.
Field
leaderPinStatus
lpMin
lpMax
This excerpt from _an XML response shows the Leader PIN settings for an expired PIN code. In
this example, the new Leader PIN is set to "777." This three-digit string meets the requirement
established by the minimum length (lpMin) and maximum length (lpMax) settings.
EPV HTML Command
<leaderPin>777</leaderPin>
<leaderPinStatus>0</leaderPinStatus>
<lpMin>3</lpMin>
<lpMax>7</lpMax>
The S6200/S6800 Media Server can send commands to the EPV server to update conference
schedule data. The cmdURI parameter in the xmldatasource section of the /usr/dcb/dbase/
admin/chdbased.reg file defines the URI where EPV commands are sent.
To construct EPV commands, you append the cmdtok parameter to an http request sent to the
URI defined by cmdURI. This parameter identifies which command the system is requesting.
The cmdtok parameter is followed by a set of command-specific parameters.
type
Description
Integer
The expiration status of the Leader PIN for a vFlow
conference. Where,
-1
(Valid) The Leader PIN is valid and is not set
to expire within the next 15 days. The system
does not play a warning regarding pending
expiration. (default)
0
(Expired) The Leader PIN has expired.
The system prompts the user, "This Leader
PIN has expired and must be changed."
1-15
(Expiring) The Leader PIN will expire in this
number of days.
The system prompts the user, "This Leader
PIN is set to expire in <number> of days.
Press 1 to change or star (*) to defer."
Integer
Minimum string length for a new Leader PIN.
0 - 16, or the maximum value allowed by the system
configuration.
The default entry, 0 ,causes the system to user the
system-wide setting.
Integer
Maximum string length for a new Leader PIN.
0 - 16, or the maximum value allowed by the system
configuration.
The default entry, 0 ,causes the system to use the
system-wide setting