Jumper
Status
CN101
J9
17.4
Minimum startup configuration
Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
Power supply unit
Table 6: Minimum startup configuration - components
RX200 S8
Description
3-5 position: Normal operation (default)
Password Clear and Recovery BIOS
disabled
1-2 position: Password Clear enabled
5-6 position: Recovery BIOS enabled
1-2 position: Normal operation (default)
2-3 position: Clear CMOS data and restore
default settings
Notes
no TPM, UFM or expansion cards installed
installed in socket CPU 1
installed in slot DIMM 1A
installed in bay 1
Upgrade and Maintenance Manual
Appendix
335