15.6.1 Preliminary steps

"Locating the defective server" on page 43
Ê
"Note on network settings recovery" on page 304
Ê
"Disabling SVOM boot watchdog functionality" on page 64
Ê
"Disabling BitLocker functionality" on page 63
Ê
"Shutting down the server" on page 46
Ê
"Disconnecting the server from the mains" on page 47
Ê
Ê Disconnect all external cables.
"Getting access to the component" on page 47
Ê
"Removing the air duct" on page 62
Ê
Ê Remove all memory modules, see section
page
207.
I
Before removing the memory modules, take a note on the installation
slot number for each memory module. Make sure that you reinstall
the memory modules in the slot they were located before the
replacement.
Ê Remove all heat sinks, see section
Ê Remove all expansion cards, see section
on page
152.
I
Before removing the expansion cards, take a note on the installation
slot number for each card. Make sure that you reinstall the card in the
slot it was located before the replacement.
"Removing the defective front LAN card" on page 262
Ê
"Removing the UFM" on page 285
Ê
I
Remove the UFM spacer from the defective system board and fasten
it with the UFM screw to the UFM board.
"Replacing the onboard SAS enabling key" on page 302
Ê
Ê Remove all fan modules, see section
on page
133.
I
Check if all fan modules are uniquely identified so that you can
reinsert them into their original bays.
RX200 S8
"Removing the heat sink" on page
(if applicable)
Upgrade and Maintenance Manual
System board and components
"Removing a memory module" on
"Expansion cards and riser cards"
(if applicable)
"Removing the defective fan module"
223.
(if applicable)