Installing The New Fan Module; Concluding Steps - Fujitsu PRIMERGY RX200 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX200 S8:
Table of Contents

Advertisement

Fans
8.2.3

Installing the new fan module

Figure 63: Installing the fan module
Ê Insert the fan module (1).
Ê First press down the rubber pins on the connector side (A), until they engage
(2).
Ê Then press down the rubber pins on the opposite side, until they engage (3).
8.2.4

Concluding steps

"Installing the fan cover" on page 53
Ê
"Sliding the server into the rack" on page 56
Ê
"Performing a fan test after replacing a defective fan" on page 89
Ê
I
When a fan module fails, the remaining fan modules will start operating
at full speed. After the defective fan module has been replaced, all fan
modules will continue to run at full speed for a couple of minutes, before
resetting to a lower speed.
Ensure that all fan modules reset to a normal operating speed.
134
A
Upgrade and Maintenance Manual
RX200 S8

Advertisement

Table of Contents
loading

Table of Contents