Basic Information - Fujitsu PRIMERGY RX200 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX200 S8:
Table of Contents

Advertisement

Fans
8.1

Basic information

Base units are supplied with four hot-plug fan modules (single CPU
configuration and depending on CPU type) or six hot-plug fan modules (two
CPUs configuration and depending on CPU type). Each fan module consists of
two fans, implemented in one housing.
Base units with four fan modules operate in a 1 of 4 redundancy, base units with
six fan modules operate in a 1 of 6 redundancy. In other words, if one of the four
or six fan modules fails, the system will operate without any problem. The failed
fan module can be exchanged without shutting down the server.
PWR 2
PWR 1
PCH
Slot riser card / slot 4
CPU 2 DIMM 1E
CPU 2 DIMM 2E
CPU 2 DIMM 3E
CPU 2 DIMM 1F
CPU 2 DIMM 2F
CPU 2 DIMM 3F
CPU 2
CPU 2 DIMM 3H
CPU 2 DIMM 2H
CPU 2 DIMM 1H
CPU 2 DIMM 3G
CPU 2 DIMM 2G
CPU 2 DIMM 1G
Figure 61: Numbering of the fan modules
132
Front
K
Panel
SATA 1
SAS 1
BP
PWR
Front LAN M
SMB
SAS
K
K
K
K
INDICATE
CSS
K
Battery
Upgrade and Maintenance Manual
FAN
11/12
FAN
9/10
FAN
7/8
FAN
5/6
FAN
3/4
FAN
1/2
RX200 S8