7.6.2

Removing the defective 8xHDD backplane

Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing the 2.5-inch HDD/SSD module" on page 114
I
The HDD/SSD modules need not to be completely removed. But if
you want to completely remove them nevertheless, check if all
HDD/SSD modules are uniquely identified so that you can reinsert
them into their original bays.
Figure 49: Disconnecting cables from the 8xHDDbackplane
Ê Disconnect the following cables from the 8xHDD backplane:
– (1) SAS data cable channel A from connector "CN1"
– (2) power cable from connector "CN20"
2
– (3) I
C cable (HDD monitoring) from connector "CN14" (if applicable)
Ê Disconnect the SAS data cable (4) from the RAID controller connector
"MLC1".
For the cable plan see section
Ê Remove all fan modules as described in section
fan module" on page
I
Check if all fan modules are uniquely identified so that you can
reinsert them into their original bays.
RX200 S8
"Cabling" on page
133.
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
314.
"Removing the defective
121