Expansion cards and backup units
9.5
Backup units (BBU/FBU)
9.5.1
Basic information
The server offers different backup units depending on the used RAID controller:
– BBU (Battery Backup Unit)
– FBU (Flash Backup Unit)
The backup unit backs up the memory contents of the connected SAS RAID
controller in the event of a power failure. You can install one backup unit.
9.5.2
Installing a BBU
Upgrade and Repair Unit
(URU)
Tools: tool-less
9.5.2.1
Preliminary steps
"Disabling SVOM boot watchdog functionality" on page 64
Ê
"Shutting down the server" on page 46
Ê
"Disconnecting the server from the mains" on page 47
Ê
"Getting access to the component" on page 47
Ê
"Removing the riser module 3" on page 60
Ê
9.5.2.2
Connecting the BBU cable to the BBU
I
The BBU cable is available in different length. You need the short cable
if the used RAID controller is installed in slot 4.
V
CAUTION!
Do not connect the cable using excessive force, the connector is weak.
172
Upgrade and Maintenance Manual
Hardware: 15 minutes
RX200 S8