Power supply
Replace the power supply unit after specifying the one that breaks
down at work by revitalization.
Both power supply units must be of the same type.
Note for servers using CMA (Cable Management Arm)
Regarding of replacing power supply units, additional tasks are needed, due to
an interference between CMA stopper and the power supply units.
Ê Push the lock spring inward to unlock the CMA stopper (see figure 27).
Ê Remove the CMA stopper with the mounted crossbar (see figure 28).
Ê Hold the CMA stopper, the crossbar and the CMA arm including cables in
the right hand.
Ê Remove the power supply unit (see figure 29) and install the new power
supply unit carefully.
Ê Mount the complete assembly (CMA stopper, the crossbar and the CMA
arm) again into the rail.
6.4.1

Preliminary steps

"Locating the defective server" on page 43
Ê
Ê Check which power supply unit is defective.
A power supply unit is defective when the indicator on the power supply unit
lights up orange (see section
page
331)
Ê Only when replacing a power supply unit in a non-redundant configuration:
"Shutting down the server" on page 46
Ê Remove the power cord from the defective power supply unit as described
in section
"Disconnecting the server from the mains" on page 47
6.4.2

Removing the defective power supply unit

Ê Remove the power supply unit as described in section
supply unit" on page
100
"Indicators on power supply units" on
98.