Fujitsu PRIMERGY RX200 S8 Upgrade And Maintenance Manual page 328

Hide thumbs Also See for PRIMERGY RX200 S8:
Table of Contents

Advertisement

Appendix
The LEDs have the following meaning:
LED
A - Identification blue on
B - CSS
(Customer Self
Service)
C - GEL
(Global Error
LED)
F - Controller
G - CPU
H - Memory
module
I - iRMC
K - Fans
L - Battery
328
Indicator
Meaning
server is identified via the ServerView
Operations Manager
blue flashing
local monitor off
off
no error (CSS component)
yellow on
indicates a prefailure (CSS component)
yellow flashing indicates a failure (CSS component)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
– over temperature measured by one of
– sensor is defective
– CPU error
– software detected an error
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
off
CPU okay
orange on
CPU failure
off
memory module running
orange on
memory module failure
off
iRMC S4 inactive
green flashing
iRMC S4 okay
off
fan running
orange on
fan failure
off
battery running
orange on
battery failure
Upgrade and Maintenance Manual
the sensors
RX200 S8

Advertisement

Table of Contents
loading

Table of Contents