Requirements For The Installation Area; Requirements For The Waste Water Connection; Requirements For The Fresh Water Connection - Meiko M-iClean H Series Operating Instructions Manual

Hood type dishwashing machine
Hide thumbs Also See for M-iClean H Series:
Table of Contents

Advertisement

6.1.2
6.1.3
6.1.4
9750359
Note
If there is any suspicion of transportation damage, the shipping company and
MEIKO must be informed immediately in writing. Photograph any damaged parts
and send the pictures to MEIKO.

Requirements for the installation area

The dishwashing machine is only frost-proof in as-delivered state or if equipped with
special features (optional: frost removal).
Installation of the dishwashing machine in an area where the ambient temperature is
below 0° C can result in damage to the internal water circuit components (e.g.
pump, solenoid valve, boiler, etc.).
Ensure that the storage and installation locations are always frost free.
There is a danger of slipping in the working area due to the use of water.
After assembly, put in place non-slip floor coverings in the working area based
on the general/location-specific safety regulations.

Requirements for the waste water connection

A waste water pump is integrated into the drain pump.
Connect the drainage hose to the locally available waste water pipe.
– For Australia only:
The drainage hose needs to have a watertight connection to a waste fitting
complying with AS 1589 AS 2887, a sanitary plumbing pipe or fitting comply-
ing with AS/NZS 1260.
Depending on the dishwasher application, a grease trap may be included,
based on the general/location-specific regulations.
For dishwashers with GiO MODULE, the maximum drain height must be con-
sidered (see dimensional drawing).

Requirements for the fresh water connection

Note
Where the water conductivity is σ < 100 µS/cm, the stainless steel variant of Air-
Concept must be used. This is the case when using a reverse osmosis (GiO) or de-
mineralisation system, for example.
For Australia only:
All work carried out must be in accordance with AS/NZS 3500.1!
Fresh water connections and their components must be carried out in accord-
ance with local regulations, e.g. EN 1717/DIN 1988-100. The fresh water must
be of the same quality as drinking water in microbiological terms. This also
applies to processed water.
The basic model of the dishwashing machine features an air gap (type AA or AB as
per EN 1717 or EN 61770). In the case of SVGW (Switzerland) and other countries,
a type EA safety device is also required in front of the connecting hose, depending
on the machine version. Installation components and materials must be suitable and
permitted in accordance with local regulations. A solenoid valve is integrated into the
dishwashing machine's fresh water line. This, together with the leakage detector in
the floor tray in the frame, ensures that the fresh water inlet within the machine is
shut off in the event of a leak.
Pressure range of the fresh water supply flow pressure upstream of the sole-
noid valve:
Machines with no GiO MODULE:
0.6 – 5 bar (60–500 kPa)
22 / 62