Requirements for the installation area

The dishwashing machine is only frost-proof in as-delivered state or if equipped with
special features (optional: frost removal).
Installation of the dishwashing machine in an area where the ambient temperature is
below 0° C can result in damage to the internal water circuit components (e.g.
pump, solenoid valve, boiler, etc.).
Ensure that the storage and installation locations are always frost free.
There is a danger of slipping in the working area due to the use of water.
After assembly, put in place non-slip floor coverings in the working area based
on the general/location-specific safety regulations.

Requirements for the waste water connection

A waste water pump is integrated into the drain pipe.
At the installation location an odour seal is provided (further information in the
dimensional drawing).
Connect the drainage hose to the locally available waste water pipe.
– For Australia only:
The drainage hose needs to have a watertight connection to a waste fitting
complying with AS 1589 AS 2887, a sanitary plumbing pipe or fitting comply-
ing with AS/NZS 1260.
Depending on the dishwashing machine application, a grease trap may be in-
cluded based on the general/location-specific regulations.
For machines with GiO module, attention must be paid to the specifications for
waste water connection in the operating and service instructions included with
the GiO module.

Requirements for the fresh water connection

Note
Where the water conductivity is σ < 100 µS/cm, the stainless steel variant of Air-
Concept must be used. This is the case when using a reverse osmosis (GiO) or de-
mineralisation system, for example.
Fresh water connections must be made as per EN 1717 or local regulations.
The basic model of the dishwashing machine features an air gap (type AA as per
EN 1717) and does not require any other safety equipment in the water supply.
The water pressure for the fresh water supply before the solenoid valve must be in
the following pressure range:
Machines with no GiO Module:
0.6 – 5 bar (60–500 kPa)
Machines with GiO Module or ActiveClean water softener:
1 – 5 bar (100 – 500 kPa)
If the minimum pressure flow is too low, increase the pressure using a booster
pump. If the maximum pressure is exceeded, limit the pressure using a pressure
regulator.
25 / 72
Design and construction subject to change without prior notice!