7.8 Temperature sensors/temperature limit switches

All safety temperature limiters and temperature sensors which have been loosely
rolled must be positioned in their correspondingly highlighted location.
CAUTION:
Do not bend the capillary filling pipe, as otherwise the tem-
perature probe could become damaged and unserviceable!
Observe the instructions on installation and removal in the
service instructions!

7.9 Fresh water connection

The water-carrying pipes and components are not frost-proof. If the temperature of
the place where the appliance has been installed can fall below 5°C, suitable pre-
cautions for protection against frost must be taken.
Information on nominal widths, diameters, etc. relate to the connections on the
machine.
Installations on site must be dimensioned to match local conditions (e.g. cable
arrangements, access lengths). Media and power connection of the machine
are described in the service instructions.
The connections must be made by approved professionals.
All parameters for the media and energy supplies must be maintained at a
constant level during all the operations.
Fresh water connections must be carried out in accordance with the require-
ments of the local regulations (e.g. Germany DIN 1988).
The owner/operator must install a shut-off device in each water supply
pipe/hose; the device must be accessible to operating personnel.
A supply disconnection has been installed depending on the machine version.
Refer to the service instructions for more detailed information.
Waste water connections must be implemented in accordance with local regu-
lations (for Germany e.g. DIN 1986).
When using water softening devices, partial desalination or complete desalina-
tion cartridges, a local shut-off device, a local particulate filter, a local non-
return device and a local vacuum breaker must be provided by the own-
er/operator.
Unless stated to the contrary, a minimum flow pressure of 2.5 bar and a maxi-
mum flow pressure of 5 bar must be guaranteed by the owner/operator.
It is possible to clean the dirt screens without turning off the
main water supply. The water supply is automatically cut
off when the lower component in which the screen is locat-
ed is unscrewed. This enables the screen to be cleaned
during maintenance.
Information on the water quantities, quality and tempera-
tures needed can be found in the installation plan.
The water quality must also comply with the requirements of the Commercial Dish-
Washing Association. (http://www.vgg-online.de.)
Keep the feed water temperature of the water line supplying the final rinse compo-
nents to a minimum to achieve optimum results with potentially installed heat re-
covery components.