Table 1.40 Display Items Of [Fans] Window; Table 1.41 [Fans] Window Button - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Web-UI (Web User Interface) Operations
Remarks
If the abnormality in rotational frequency of a fan is detected again after executing [Status Clear], then, the
status changes to [Failed Status]. Accordingly, even if the status of a fan, having abnormal rotational
frequency from the beginning is cleared, the status remains as [Failed].

TABLE 1.40 Display items of [Fans] window

Items
Fan Redundancy
Fan Redundancy Displays the redundancy status of fan.
·
·
·
PSU/FANU Slot
Displays the slot location of the PSU or FANU to which the FANM belongs.
Status
Displays the status of each fan
·
·
·
·
Part Number
Displays the part number of the fan.
Fan Speed(rpm)
Displays the rotational frequency (rpm) of each fan.
Threshold(rpm)
Warning(Low/High)
Critical(Low/High)
Airflow Volume
Displays the airflow.
Button
Status Clear
Clears the status of fan.
(1)
Menu Operation
[System] – [Fans]
(2)
Window Operations
1.
Click the [Status Clear] button.
Dialog box for confirmation appears.
2.
Click the [OK] button to clear the Status of the fan and, click the [Cancel] button when you do not
want to clear the fan status.
[Message]
This section describes the messages to be displayed on this window.
Message Number
I_00029
Status Clear completed.
E_00123
Failed to clear the status.
For details on the messages displayed on the window, see
(C122-E178EN).
Redundant: The Fans are Redundant
Non-Redundant: Sufficient Resource: Redundancy of fan is lost, however, there
are sufficient fans, to continue the operations of the system.
Non-Redundant: Insufficient Resource: The number of fans is less due to
redundancy, and fans to continue operations of the system are sufficient.
OK
Not-present
Warning
Failed
Displays the lower limit and upper limit of the warning-level
rotational frequency of each fan. (If the rotational frequency is
lower or upper than this limit, it is considered to be abnormal)
Displays the lower limit and upper limit of the critical-level
rotational frequency of each fan. (If the rotational frequency is
lower or upper than this limit, it is considered to be abnormal)

TABLE 1.41 [Fans] Window Button

Message
Description
Description
PRIMEQUEST 2000 Series Message Reference

Advertisement

Table of Contents
loading

Table of Contents