CHAPTER 11 Error Notification and Maintenance (Contents, Methods, and Procedures)
11.4 Collecting Maintenance Data

FIGURE 11.14 [System Event Log Filtering Condition] window in PRIMEQUEST 2800B

2. Specify the condition to filter events. Then, click the [Apply] button.
The [System Event Log] window appears again. The window displays the events matching the specified
conditions.
To clear the specified conditions and return to the [System Event Log] window, click the [Cancel] button.
To clear the specified conditions and restore the default values, click the [Default Setting] button.

TABLE 11.5 Setting and display items in the [System Event Log Filtering Condition] window

Item
Severity
Partition (*1)
Unit
Select the severity of events to display by using the following check boxes.
You can check multiple check boxes.
- Error
- Warning
- Info
All check boxes are checked by default.
Select the partition to display.
Select the [All] or [Specified] radio button.
If you select [All], filtering by partition will not be applied. In this case, the
check boxes for partitions in [Specified] are grayed out and cannot be
checked.
If you select [Specified], you can check the check boxes for selecting a
partition.
Even after a switch to [All] and back to [Specified], the window retains the
selections made with the [Specified] check boxes
[All] is grayed out and cannot be selected for users with Partition Operator
accounts. Also, they can select partition filtering only for the target partition.
The default settings are as follows:
- For other than Partition Operator, [All] radio button.
- For Partition Operator, [Specified] radio button and target partition.
Select the units to display.
Select the [All] or [Specified] radio button.
If you select [All], filtering by unit is not applied.
If you select [Specified], you can set filtering by unit. Check the check box of a
unit to display the events of that unit.
Even after a switch to [All] and back to [Specified], the window retains the
selections made with the [Specified] check boxes.