Table 1.147 Display Items And Set Items Of [Add Schedule] Window; Table 1.148 [Add Schedule] Window Buttons - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Web-UI (Web User Interface) Operations

TABLE 1.147 Display Items and Set Items of [Add Schedule] Window

Items
Type
Pattern
Term
On Time
Off Time

TABLE 1.148 [Add Schedule] Window Buttons

Buttons
Apply
If the [Apply] button is clicked, the schedule information specified in each item is applied to the
partition.
Cancel
If the [Cancel] button is clicked, returns to the original sate without applying the schedule
information specified in each item.
[Message]
This section describes the messages to be displayed on this window.
Message Number
I_00013
Setting completed.
W_00414
Invalid Date Format
W_00415
The duplicate On/Off Time is found.
W_00416
Both On/ Off Time are disabled.
Select the types of schedule to be set in the syetm.
Daily: Select when you want to execute every day
Weekly: Select when you want to execute every week
Monthly: Select when you want to execute every month
Special: Select when you want to execute on a particular day every year.
(The useful range of Special becomes only a specified day.)
If the schedule overlaps on the same day, it is processed according to the
following priority order.
Special > Monthly > Weekly > Daily
By default, it is not selected.
Specify the schedule pattern corresponding to the types of the schedule.
Weekly : Day in a week (Sun ~ Sat)
Monthly: Period in a month
Special: Specified month
Default settings are as follows.
Day in a week: Not selected
Period: From : 1 To: 1
Specified date: Jan/1
Specify the period of the schedule according to the type and pattern of the
schedule.
Daily: Starting month and date, and ending month and date
Weekly: Starting month and ending month
Monthly: Starting month and ending month
Default settings are as follows.
Daily: From: Jan / 1 To: Jan / 1
Weekly: From: Jan To: Jan
Monthly: From: Jan To: Jan
On the specified execution date, set whether the power-supply is to be turned
ON.
If the power-supply is to be ON, set the time.
Time is specified in24 hours. Minute specifies the interval of 10 minutes as 00,
10, 20, 30, 40, and 50.
Set whether the power-supply is OFF on the specified execution date.
If the power-supply is OFF, set the time.
Time is specified in 24 hours. Minute is specified in the interval of 10 minutes,
as 00, 10, 20, 30, 40, and 50.
Message
Description
Description

Advertisement

Table of Contents
loading