CiM-550 IP Enabled Satellite Modem
SNMP interface
13.4.1.8 C
M SNMP T
I
The cim550 has the ability to send out SNMP traps when certain events occur in the
modem. For example, when the cim550 boots it sends out a coldstart trap and 3 linkup
traps, one for each interface that is brought up. The cim550 also sends out traps when an
alarm or a fault occurs in the modem. These include unit faults, TX faults, and RX faults.
A trap is sent both when a fault occurs and is cleared.
The cim550 supports both SNMPv1 traps and SNMPv2 notifications. Which style of
traps the cim 550 sends can be configured by the user using the cimSnmpTrapVersion
OID.
The following are the MIB2 v1traps/v2 notifications that the cim550 supports.
CiM550 MIB2 SNMPv1 traps:
CiM550 MIB2 SNMPv2 notifications:
The following tables are the Alarms and Faults v1 traps / v2 notifications that the cim550
supports.
CiM550 Alarms and Faults SNMPv1 traps:
RAPS
Cold Start
Warm Start
Link Down
Link Up
Authentication Failure
Cold Start
Warm Start
Link Down
Link Up
Authentication Failure
cim550ModemUnitFaultsTrap
cim550ModemTxTrafficFaultsTrap
cim550ModemRxTrafficFaultsTrap
1
2
3
4
5
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.6.3.1.1.5.3
1.3.6.1.6.3.1.1.5.4
1.3.6.1.6.3.1.1.5.5
624751
624752
624753
233