Figure 76 RMON statistics
Table 28 Field description
Field
Number of Received Bytes
Number of Received Packets
Number of Received Broadcasting
Packets
Number of Received Multicast Packets
Number of Received Packets With CRC
Check Failed
Number of Received Packets Smaller
Than 64 Bytes
Number of Received Packets Larger
Than 1518 Bytes
Number of Received Packets Smaller
Than 64 Bytes And FCS Check Failed
Description
Total number of octets received by the interface, corresponding to the
MIB node etherStatsOctets.
Total number of packets received by the interface, corresponding to
the MIB node etherStatsPkts.
Total number of broadcast packets received by the interface,
corresponding to the MIB node etherStatsBroadcastPkts.
Total number of multicast packets received by the interface,
corresponding to the MIB node etherStatsMulticastPkts.
Total number of packets with CRC errors received on the interface,
corresponding to the MIB node etherStatsCRCAlignErrors.
Total number of undersize packets (shorter than 64 octets) received
by the interface, corresponding to the MIB node
etherStatsUndersizePkts.
Total number of oversize packets (longer than 1518 octets) received
by the interface, corresponding to the MIB node
etherStatsOversizePkts.
Total number of undersize packets (shorter than 64 octets) with CRC
errors received by the interface, corresponding to the MIB node
etherStatsFragments.