HP 830 Series Configuration Manual page 68

Poe+ unified wired-wlan switch switching engine web-based
Hide thumbs Also See for HP 830 Series:
Table of Contents

Advertisement

Figure 47 Configuring the rate of GigabitEthernet 1/0/4
2.
Batch configure the autonegotiation rate range on GigabitEthernet 1/0/1, GigabitEthernet
1/0/2, and GigabitEthernet 1/0/3 as 100 Mbps:
a.
On the Setup page, select Auto 100 from the Speed list.
b.
Select 1, 2, and 3 on the chassis front panel. 1, 2, and 3 represent ports GigabitEthernet
1/0/1, GigabitEthernet 1/0/2, and GigabitEthernet 1/0/3.
c.
Click Apply.
56