Dell Force10 Z9000 Configuration Manual page 389

Ftos configuration guide for z9000 system
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

To add a physical interface to a port channel, use these commands in the following sequence in the
INTERFACE mode of a port channel:
Step
Command Syntax
channel-member interface
1
show config
2
To view the port channel's status and channel members in a tabular format, use the
port-channel brief
Figure 19-11. show interfaces port-channel brief Command Example
FTOS#show int port brief
LAG Mode
Status
1
L2L3
up
2
L2L3
up
FTOS#
Command Mode
INTERFACE
PORT-CHANNEL
INTERFACE
PORT-CHANNEL
command in the EXEC Privilege mode.
Uptime
Ports
00:06:03
Gi 13/6
Gi 13/12
00:06:03
Gi 13/7
Gi 13/8
Gi 13/13
Gi 13/14
Purpose
Add the interface to a port channel.
The interface variable is the physical interface
type and slot/port information.
Double check that the interface was added to
the port channel.
(Up) *
(Up)
(Up) *
(Up)
(Up)
(Up)
show interfaces
Interfaces | 389