Dell Force10 Z9000 Configuration Manual page 290

Ftos configuration guide for z9000 system
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

Figure 12-3. Running Offline Diagnostics on a Z-Series Standalone Unit
FTOS#diag stack-unit 1 alllevels
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable to shut
directly connected ports
Proceed with Diags [confirm yes/no]: yes
00:03:35: %S50N:1 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 1
00:03:35 : Approximate time to complete these Diags ... 6 Min
S50N#00:09:32 : Diagnostic test results are stored on file: flash:/TestReport-SU-0.txt
00:09:37: %S50N:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 0
Diags completed... Rebooting the system now!!!
[reboot output omitted]
S50N#00:01:35: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console by
dir
Directory of flash:
1
drw-
16384
2
drwx
3
drw-
4
d---
5
-rw-
6
-rw-
12632
flash: 3104256 bytes total (3086336 bytes free)
4. View the results of the diagnostic tests using the command
mode, as shown in the following example.
|
Z-Series Debugging and Diagnostics
290
Jan 01 1980 00:00:00 +00:00 .
1536
Feb 29 1996 00:05:22 +00:00 ..
512
Aug 15 1996 23:09:48 +00:00 TRACE_LOG_DIR
512
Aug 15 1996 23:09:52 +00:00 ADMIN_DIR
3854
Sep 24 1996 03:43:46 +00:00 startup-config
Nov 05 2008 17:15:16 +00:00 TestReport-SU-1.txt
console
from EXEC Privilege
show file flash://