Table 10-5. IPv4Flow CAM Sub-partition Sizes
Partition
QoS
System Flow
Trace Lists
You can re-configure the amount of space allocated for each type of entry
an amount of CAM space for all types and in the order shown in
•
The IPv4Flow configuration is applied to entire system when you enter the command
from CONFIGURATION mode, however, you must save the running-configuration to affect the
change.
The amount of space that is allocated among the sub-partitions must be equal to the amount of CAM space
allocated to IPv4Flowby the selected CAM profile (refer to
total allocated space is not correct.
Message 3 IPv4Flow Configuration Error
% Error: Total size must add up to match IPv4flow size of 24K required by the
configured profile.
The minimum amount of space that can be allocated to any sub-partition is 1K, except for System flow, for
which the minimum is 4K.
To re-allocate CAM space within the IPv4Flow partition on the entire system:
Step
Task
1
Re-allocate CAM space within the
IPv4Flow partition.
2
Save the running-configuration.
3
Verify that the new CAM configuration will
be written to the CAM on the next boot.
4
Reload the system.
FTOS(conf)#cam-ipv4flow default
FTOS#copy running-config startup-config
File with same name already exist.
Proceed to copy the file [confirm yes/no]: yes
!
3914 bytes successfully copied
FTOS#sh cam-ipv4flow
-- Chassis Cam Ipv4Flow --
Space Allocated
Space Allocated
(EtherScale)
(TeraScale)
8K
5K
1
Command Syntax
cam-ipv4flow
copy running-config startup-config
show cam-ipv4flow
reload
Space Allocated
(ExaScale)
2K
2K
5K
5K
1K
1K
.
FTOS requires that you specify
Table
10-5.
Table
10-1.);
Message 3
Command Mode
CONFIGURATION
EXEC Privilege
EXEC Privilege
EXEC Privilege
Content Addressable Memory (CAM) | 271
cam-ipv4flow
is displayed if the