RGBHV+Stereo to CatPro Boards with TXs & RXs
Routing Path A – Cabling and the RX Hardware Method
Source
For Routing Path A, the hardware on the RX Module (which works in conjunction with the CatPro
output board) is adjusted to obtain a sharp picture on the Destination Monitor. The hardware includes
Gain and Peak potentiometers and an Adjust knob for skew (FIG. 47). The Adjust knob also adjusts
volume.
To cable the system for Routing Path A:
1.
Place all source and destination devices in their final installation locations.
2.
Cable the complete routing paths from the source devices to the destination devices (FIG. 46). All
cable should be the actual cable that will be used.
FIG. 46
Routing Path A
Gain and Peak
The Gain and Peak potentiometers (pots) on a CatPro RX Module are used to compensate for the overall
cable length. For Routing Path A, the CatPro supported cable between a CatPro output board and its
RX Module can be up to 1,000 ft. (305 m).
LED for Adjust knob
FIG. 47
CatPro RX Module
82
RGBHV/HD-15 Input Board
Gain and Peak pots
CatPro Output Board
CatPro RX Module
Adjust knob for skew and volume
Destination
gain & peak
Modula Instruction Manual