The following procedure needs to be completed for all the sources used in Routing Path C.
To calibrate a TX Module to its CatPro input (using the Wizard):
1.
Disconnect an RX Module from one of the CatPro output boards.
2.
Using the 3-foot Cat5e cable, connect the Temporary RX Module Unit to the now empty connector
on the CatPro output board (FIG. 60).
FIG. 60
Routing Path C ready for calibration with the Wizard
3.
Route the signal for the first source device (the test image file should be open on the source) to the
output on the CatPro output board that is connected to the Temporary RX Module Unit.
4.
Open the CatPro Wizard on the Control PC.
5.
Adjust the display using the CatPro Wizard according to Steps 5 through 10 on page 84.
6.
Disconnect the Temporary RX Module Unit and reconnect the permanent RX Module to the CatPro
output board.
7.
Repeat Steps 1 through 6 for all the sources used in Routing Path C (if source devices and their
cable runs are similar, see the note below).
8.
From the Options menu, select Save to System to restore the settings upon power up. The Save to
System dialog box opens.
9.
Click OK.
10. From the File menu, select Save As to save a backup file to the PC.
11. Enter a file name, and Click OK.
Note: If the same types of source devices are connected to the same types of destination devices
with similar cable runs, the settings for the file saved in Step 9 can be applied to those sources (see
page 88).
The following procedure needs to be completed for all the destinations that will be used in Routing
Path C.
To calibrate a CatPro output to its RX Module (using the RX Hardware Method):
1.
Route a source to the output to be adjusted on the CatPro output board.
2.
On the RX Module connected to the output, adjust the video display using the Gain and Peak
potentiometers and the Adjust knob (see page 83).
3.
Repeat for all the outputs (destinations) on the board that will be used in Routing Path C.
If undesirable display conditions persist after using the adjustment procedure, see the Troubleshooting
section on the following page.