Enclosure Configurations

Enclosure Configurations
Each Modula enclosure holds up to 16 boards with 4 connectors each. The ratio of input and output
boards depends on the model. Some models are available in configurations up to 32x32 in increments of
four. Flex-slot models allow configurations that are either input or output heavy. All Modula enclosures
can be added to in the field if not completely full when initially ordered.
32x32 Enclosures
Flex-Slot Enclosures
The flex-slot models have three designated slots that can be used for either input or output boards. For
example, an enclosure configured as 4x60 can be reconfigured to 16x48 by replacing the first three
output boards with input boards.*
1 Input board
FIG. 7
Flex-slot enclosures
* Changing or adding boards to an enclosure often requires a new configuration file.
Modula Instruction Manual
Configured for 32x32 with 8 input boards and 8 output boards
Subset configurations in increments of four, e.g., 4x32, 12x8, 16x16, 20x4, or 28x12
16x48 Flex-Slot Enclosure
Configured for 16x48 with 4 input boards and 12 output boards
1 input board minimum and 15 output boards maximum
Flex-slots 2, 3 and 4 can be used for output boards instead of input boards
Configurations of 4x60, 8x56, or 12x52 are also possible
48x16 Flex-Slot Enclosure
Configured for 48x16 with 12 input boards and 4 output boards
15 input boards maximum and 1 output board minimum
Flex-slots 13, 14, and 15 can be used for input boards instead of output boards
Configurations of 60x4, 56x8, or 52x12 are also possible
16x48 flex-slot enclosure
12 output boards
48x16 flex-slot enclosure
Flex-slots can hold either
input or output boards
Enclosure Configurations
12 input boards
1 Output board