Appendix E – Vertical Interval Sync (VIS)
4.
In the Hardware view, right click the enclosure with the VIS board and select Manage Board Slots
from the shortcut menu.
5.
Check the Vertical Interval Sync box to assign the board to an enclosure.
Click OK.
6.
Repeat Steps 4 and 5 for all enclosures with a VIS board.
7.
In the Virtual Matrix view, right click the first video virtual matrix that participates in the vertical
sync and select Assign Signals from the shortcut menu.
The Assign Virtual Matrix Signals dialog box opens.
8.
Check the Vertical Interval Sync check box to assign the VIS board to the virtual matrix.
Click OK.
Click OK to close the next window.
9.
Repeat Steps 7 and 8 for all remaining video virtual matrices that contain signals that need to be
synchronized.
10. Connect a PC to the enclosure's serial port.
For XNConnect version 2.4.0 – from the Configure menu, select Configure All.
The system automatically reboots all devices.
Or
For XNConnect versions prior to 2.4.0 – from the Configure menu, select Reboot All Devices.
11. Execute a test switch that includes a signal routed on the new board to ensure the system is working
correctly.
If the test switch does not execute correctly, contact technical support (see page 43).
184
Vertical Interval Sync
Vertical Interval Sync
Modula Instruction Manual