27
:SBUS<n> Commands
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID
Command Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID <frame_id>
<frame_id> ::= {ALL | <frame #>}
<frame #> ::= integer from 1-2047
The :SBUS<N>:FLEXray:TRIGger:EVENt:BSS:ID command sets the frame ID
used by the Byte Start Sequence (BSS) event trigger. This setting is only
valid if the trigger mode is EVENt and the EVENt:TYPE is BSS.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID?
The :SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID? query returns the current
frame ID setting for the Byte Start Sequence (BSS) event trigger setup.
Return Format
<frame_id><NL>
<frame_id> ::= {ALL | <frame #>}
<frame #> ::= integer from 1-2047
See Also
682
(see
page
1138)
"Introduction to :TRIGger Commands"
":SBUS<n>:FLEXray:TRIGger:EVENt:TYPE"
":SBUS<n>:FLEXray:TRIGger:EVENt:AUToset"
":TRIGger:MODE"
on page 886
":SBUS<n>:FLEXray:TRIGger"