DSO-X 3024A DSO-X 3034A DSO-X 3054A The Agilent InfiniiVision 3000 X- Series oscilloscopes deliver these features: • 100 MHz, 200 MHz, 350 MHz, and 500 MHz bandwidth models. • 2- and 4- channel digital storage oscilloscope (DSO) models. • 2+16- channel and 4+16- channel mixed- signal oscilloscope (MSO) models.
Page 4
Quick Help. Complete instructions for using the quick help system are given in “Access the Built- In Quick Help" on page 43. For more information about InfiniiVision oscilloscopes, see: "www.agilent.com/find/scope" Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
23, “I2C/SPI Triggering and Serial Decode,” starting on page 325 • Chapter 24, “I2S Triggering and Serial Decode,” starting on page 345 • Chapter 25, “UART/RS232 Triggering and Serial Decode,” starting on page 355 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 6
[Key1], then pressing Softkey2, then pressing Softkey3 are abbreviated as follows: Press [Key1]> Softkey2 > Softkey3. The keys may be a front panel [Key] or a Softkey. Softkeys are the six keys located directly below the oscilloscope display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Use Auto Scale Compensate Passive Probes Learn the Front Panel Controls and Connectors Front Panel Overlays for Different Languages Learn the Rear Panel Connectors Learn the Oscilloscope Display Access the Built-In Quick Help Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 8
To adjust the vertical scale To adjust the vertical position To specify channel coupling To specify channel input impedance To specify bandwidth limiting To change the vertical scale knob's coarse/fine adjustment setting To invert a waveform Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 9
FFT Spectral Leakage Units for Math Waveforms Reference Waveforms To save a waveform to a reference waveform location To display a reference waveform To scale and position reference waveforms To adjust reference waveform skew Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 10
To display digital channels as a bus Digital channel signal fidelity: Probe impedance and grounding Input Impedance Probe Grounding Best Probing Practices To replace digital probe leads Serial Decode Serial Decode Options Lister Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 11
To reset the label library to the factory default Triggers Adjusting the Trigger Level Forcing a Trigger Edge Trigger Pulse Width Trigger Pattern Trigger Hex Bus Pattern Trigger Rise/Fall Time Trigger Nth Edge Burst Trigger Runt Trigger Setup and Hold Trigger Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 12
Maximum voltage at oscilloscope external trigger input Acquisition Control Running, Stopping, and Making Single Acquisitions (Run Control) Overview of Sampling Sampling Theory Aliasing Oscilloscope Bandwidth and Sample Rate Oscilloscope Rise Time Oscilloscope Bandwidth Required Memory Depth and Sample Rate Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 13
Saving Data from Segmented Memory Cursors To make cursor measurements Cursor Examples Measurements To make automatic measurements Measurements Summary Snapshot All Voltage Measurements Peak-Peak Maximum Minimum Amplitude Base Overshoot Preshoot Average DC RMS Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 14
Rising Edge Count Falling Edges Count Mixed Measurements Area Measurement Thresholds Measurement Window with Zoom Display Measurement Statistics Mask Testing To create a mask from a "golden" waveform (Automask) Mask Test Setup Options Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 15
To navigate storage locations To enter file names Recalling Setups, Masks, or Reference Waveforms To recall setup files To recall mask files To recall reference waveform files from a USB storage device Recalling Default Setups Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 16
To perform user calibration To perform hardware self test To perform front panel self test To display oscilloscope information To display the user calibration status To clean the oscilloscope To check warranty and extended services status Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 17
Instrument Utilities Setting a Password Reference Specifications and Characteristics Measurement Category Oscilloscope Measurement Category Measurement Category Definitions Transient Withstand Capability Maximum input voltage at analog inputs Maximum input voltage at digital channels Environmental Conditions Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 18
CAN/LIN Triggering and Serial Decode Setup for CAN Signals CAN Triggering CAN Serial Decode Interpreting CAN Decode CAN Totalizer Interpreting CAN Lister Data Searching for CAN Data in the Lister Setup for LIN Signals Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 19
I2S Triggering and Serial Decode Setup for I2S Signals I2S Triggering I2S Serial Decode Interpreting I2S Decode Interpreting I2S Lister Data Searching for I2S Data in the Lister UART/RS232 Triggering and Serial Decode Setup for UART/RS232 Signals Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 20
UART/RS232 Triggering UART/RS232 Serial Decode Interpreting UART/RS232 Decode UART/RS232 Totalizer Interpreting UART/RS232 Lister Data Searching for UART/RS232 Data in the Lister Index Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Getting Started Inspect the Package Contents Tilt the Oscilloscope for Easy Viewing Power-On the Oscilloscope Connect Probes to the Oscilloscope Input a Waveform Recall the Default Oscilloscope Setup Use Auto Scale Compensate Passive Probes...
Page 22
InfiniiVision 3000 X- Series oscilloscope. • Power cord (country of origin determines specific type). • Oscilloscope probes: • Two probes for 2- channel models. • Four probes for 4- channel models. • Documentation CD- ROM. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 23
N6450-61601 16-channel cable (qyt 1) 01650-82103 2-inch probe ground leads (qyt 5) 5090-4832 Grabber (qyt 20) Digital probe replacement parts are listed in the "Digital Channels" chapter. See Also • “Accessories Available" on page 294 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The LAN/VGA or GPIB module must be installed before powering on the oscilloscope. N O T E Tilt the Oscilloscope for Easy Viewing There are tabs under the oscilloscope's front feet that can be flipped out to tilt the oscilloscope. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Connect the power cord to the rear of the oscilloscope, then to a oscilloscope suitable AC voltage source. Route the power cord so the oscilloscope's feet and legs do not pinch the cord. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The 50 input protection only functions when the oscilloscope is powered on. With 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk With N2862A or N2863A 10:1 probe: 300 Vrms Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Recall the Default Oscilloscope Setup To recall the default oscilloscope setup: 1 Press [Default Setup]. The default setup restores the oscilloscope's default settings. This places the oscilloscope in a known operating condition. The major default settings are: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Use Auto Scale Use [Auto Scale] to automatically configure the oscilloscope to best display the input signals. 1 Press [Auto Scale]. You should see a waveform on the oscilloscope's display similar to this: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 29
25 Hz, a duty cycle greater than 0.5%, and an amplitude of at least 10 mV peak- to- peak. Any channels that do not meet these requirements are turned off. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
On the N2862/63/90 probes, the trimmer capacitor is the yellow adjustment on the probe tip. On other probes, the trimmer capacitor is located on the probe BNC connector. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The legend for these keys is directly above them, on the display. Their functions change as you navigate through the oscilloscope's menus. For the following figure, refer to the numbered descriptions in the table that follows. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 32
You can vary the intensity control to bring out signal detail, much like an analog oscilloscope. Digital channel waveform intensity is not adjustable. More details about using the Intensity control to view signal detail are on “To adjust waveform intensity" on page 117. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 33
16, “Waveform Generator,” starting on page 231. Trigger controls These controls determine how the oscilloscope triggers to capture data. Chapter 10, “Triggers,” starting on page 129 and Chapter 11, “Trigger Mode/Coupling,” starting on page 159. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 34
For more information, see “Running, Stopping, and Making Single Acquisitions (Run Control)" on page 167. [Default Setup] Press this key to restore the oscilloscope's default settings (details on “Recall the Default Oscilloscope Setup" on page 27). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 35
• Multiplexed position knob — This position knob is used with Math, Ref, or Digital waveforms, whichever has the illuminated arrow to the left. For math and reference waveforms, the position knob acts like an analog channel vertical position knob. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 36
18, “Print (Screens),” starting on page 251. [Help] key Opens the Help Menu where you can display overview help topics and select the Language. See also “Access the Built-In Quick Help" page 43. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 37
3, “Vertical Controls,” starting on page 59. Analog channel Attach oscilloscope probes or BNC cables to these BNC connectors. inputs With the InfiniiVision 3000 X-Series oscilloscopes, you can set the input impedance of the analog channels to either 50 or 1 M .
To install a front panel overlay: 1 Gently pull on the front panel knobs to remove them. 2 Insert the overlay's side tabs into the slots on the front panel. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 39
4 Channel Overlay French 75019-94324 75019-94316 German 75019-94326 75019-94318 Italian 75019-94323 75019-94331 Japanese 75019-94311 75019-94312 Korean 75019-94329 75019-94321 Portuguese 75019-94327 75019-94319 Russian 75019-94322 75019-94315 Simplified Chinese 75019-94328 75019-94320 Spanish 75019-94325 75019-94317 Traditional Chinese 75019-94330 75019-94310 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The video output connector is always active. For optimal video quality and performance, we recommend you use a shielded video cable with ferrite cores. A DSOXGPIB GPIB module may be ordered and installed separately. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
PC to the oscilloscope via the USB device port. See “Remote Programming with Agilent IO Libraries" on page 278. Learn the Oscilloscope Display The oscilloscope display contains acquired waveforms, setup information, measurement results, and the softkey definitions. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 42
117. Information area The information area normally contains acquisition, analog channel, automatic measurement, and cursor results. Menu line This line normally contains menu name or other information associated with the selected menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Press and hold front panel key or softkey (or right-click softkey when using web browser remote front panel). Quick Help remains on the screen until another key is pressed or a knob is turned. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 44
2 Repeatedly press and release the Language softkey or rotate the Entry language knob until the desired language is selected. The following languages are available: English, French, German, Italian, Japanese, Korean, Portuguese, Russian, Simplified Chinese, Spanish, and Traditional Chinese. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 45
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Horizontal Controls To adjust the horizontal (time/div) scale To adjust the horizontal delay (position) Panning and Zooming Single or Stopped Acquisitions To change the horizontal time mode (Normal, XY, or Roll) To display the zoomed time base...
The current sample rate is displayed in the right- side information area. To adjust the horizontal (time/div) scale 1 Turn the large horizontal scale (sweep speed) knob marked change the horizontal time/div setting. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The horizontal position knob works (in the Normal time mode) while acquisitions are running or when they are stopped. When running, adjusting the horizontal scale knob changes the sample rate. When Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The screen will still contain a relatively good display if you zoom-in horizontally by a factor of 1000 and zoom-in vertically by a factor of 10 to display the information from where it was acquired. Remember that you can only make automatic measurements on displayed data. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
To clear the display and restart an acquisition in Roll mode, press the [Single] key again. Use Roll mode on low- frequency waveforms to yield a display much like a strip chart recorder. It allows the waveform to roll across the display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
(assuming the amplitude is the same on both channels): sin = Signal must be centered in “ X” Measuring Signals 90 degrees Signals phase difference out of phase in phase Figure 3 XY time mode signals, centered on display Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 51
7 Calculate the phase difference using the formula below. For example, if the first Y value is 1.688 and the second Y value is 1.031: sin = second Y 1.031 first Y = 1.688 ; = 37.65 degrees of phase shift Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
You can use Zoom to locate and horizontally expand part of the normal window for a more detailed (higher- resolution) analysis of signals. To turn on (or off) Zoom: 1 Press the zoom key (or press the [Horiz] key and then the Zoom softkey). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 53
The delay value, which is the time displayed relative to the trigger point) is momentarily displayed in the upper- right portion of the display when the delay time ( ) knob is turned. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
A small hollow triangle () at the top of the display grid marks the position of the time reference. When delay time is set to zero, the trigger point indicator ( ) overlays the time reference indicator. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
3 Press Settings, and use the Search Settings Menu to set up the selected search type. Setting up searches is similar to setting up triggers: • For setting up Edge searches, see “Edge Trigger" on page 132. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Navigating the Time Base You can use the [Navigate] key and controls to navigate through: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• The Auto zoom softkey specifies whether the waveform display is automatically zoomed to fit the marked row as you navigate. • Pressing the Scroll Lister softkey lets you use the Entry knob to scroll through data rows in the Lister display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
In the Auto play mode: • Press the navigation keys to play backward, stop, or play forward in time. You can press the keys multiple times to speed up the playback. There are three speed levels. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 59
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Vertical Controls To turn waveforms on or off (channel or math) To adjust the vertical scale To adjust the vertical position To specify channel coupling To specify channel input impedance To specify bandwidth limiting...
1 and channel 2 are turned on and the menu for channel 2 is being displayed, to turn channel 1 off, press [1] to display the channel 1 menu; then, press [1] again to turn channel 1 off. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
(see “To choose "expand about" center or ground" page 261). To specify channel coupling Coupling changes the channel's input coupling to either AC (alternating current) or DC (direct current). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
50 Ohm — matches 50 ohm cables commonly used in making high • frequency measurements, and 50 ohm active probes. When 50 Ohm input impedance is selected, it is displayed with the channel information on- screen. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Fine softkey in the Channel Menu) to toggle between fine and coarse adjustment of the vertical scale. When Fine adjustment is selected, you can change the channel's vertical sensitivity in smaller increments. The channel sensitivity remains fully calibrated when Fine is on. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Probe Menu. This menu lets you select additional probe parameters such as attenuation factor and units of measurement for the connected probe. The Channel Probe Menu changes depending on the type of probe connected. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Press the channel key. 2 Press the Probe softkey until you have selected how you want to specify the attenuation factor, choosing either Ratio or Decibels. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
200 ns difference. The skew setting is not affected by pressing [Default Setup] or [Auto Scale]. To calibrate a probe The Calibrate Probe softkey guides you through the process of calibrating probes. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 67
10:1 (+12 dB Atten) differential browser. • 10:1 (+20 dB Atten) single- ended browser. • 10:1 (+20 dB Atten) differential browser. 6 Press the Calibrate Probe softkey and follow the instructions on the display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 68
Vertical Controls For more information on InfiniiMax probes and accessories, see the probe's User's Guide. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Math Waveforms To display math waveforms To perform a transform function on an arithmetic operation To adjust the math waveform scale and offset Add or Subtract Multiply Differentiate Integrate Square Root FFT Measurement Units for Math Waveforms Math functions can be performed on analog channels.
The result is displayed. 6 To re- size and re- position the math waveform, see “To adjust the math waveform scale and offset" on page 71. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
If the arrow to the left of the [Math] key is not illuminated, press the key. 2 Use the multiplexed scale and position knobs just to the right of the [Math] key to re- size and re- position the math waveform. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Multiply is useful for seeing power relationships when one of the channels is proportional to the current. Figure 5 Example of Multiply Channel 1 by Channel 2 See Also • “Units for Math Waveforms" on page 86 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Figure 6 Example of Subtract Channel 2 from Channel 1 See Also • “Units for Math Waveforms" on page 86 Differentiate d/dt (differentiate) calculates the discrete time derivative of the selected source. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 74
• d = differential waveform. • y = channel 1, 2, 3, or 4, or g(t) (internal arithmetic operation) data points. • i = data point index. • t = point- to- point time difference. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
dt plots the integral of the source using the "Trapezoidal Rule". The equation is: ∑ + Δ Where: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 76
• t = point- to- point time difference. • y = channel 1, 2, 3, or 4, or g(t) (internal arithmetic operation). • co = arbitrary constant. • i = data point index. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 77
Math Waveforms 0 V level 0 V level Figure 8 Integrate and Signal Offset See Also • “To perform a transform function on an arithmetic operation" page 71 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
FFT takes the digitized time record of the specified source and transforms it to the frequency domain. When the FFT function is selected, the FFT spectrum is plotted on the Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 79
Rectangular — good frequency resolution and amplitude accuracy, • but use only where there will be no leakage effects. Use on self- windowing waveforms such as pseudo- random noise, impulses, sine bursts, and decaying sinusoids. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 80
Pressing the FFT Preset softkey will automatically rescale the waveform and span and center will again automatically track the horizontal scale setting. 3 To make cursor measurements, press the [Cursors] key and set the Source softkey to Math: f(t). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 81
See Also • “To perform a transform function on an arithmetic operation" page 71 • “FFT Measurement Hints" on page 82 • “FFT Units" on page 83 • “FFT DC Value" on page 83 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• Make sure the probe attenuation is set correctly. The probe attenuation is set from the Channel Menu if the operand is a channel. • Set the source sensitivity so that the input signal is near full screen, but not clipped. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• Adjust frequency span for better cursor placement. • Return to the Cursors Menu to fine tune the X cursor. For more information on the use of FFTs please refer to Agilent Application Note 243, The Fundamentals of Signal Analysis at "http://cp.literature.agilent.com/litweb/pdf/5952-...
Page 84
100 kSa/s, and the oscilloscope displays the spectrum. The displayed waveform shows the components of the input signal above the Nyquist frequency to be mirrored (aliased) on the display and reflected off the right edge. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
FFT. The FFT Menu provides four windows: Hanning, Flat Top, Rectangular, and Blackman- Harris. For more information on leakage, see Agilent Application Note 243, The Fundamentals of Signal Analysis at "http://cp.literature.agilent.com/litweb/pdf/5952- 8898E.pdf." Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
A scale unit of U (undefined) will be displayed for math functions when two source channels are used and they are set to dissimilar units and the combination of units cannot be resolved. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Reference Waveforms To save a waveform to a reference waveform location To display a reference waveform To scale and position reference waveforms To adjust reference waveform skew To display reference waveform information To save/recall reference waveform files to/from a USB storage...
2 In the Reference Waveform Menu, press the Ref softkey and turn the Entry knob to select the desired reference waveform location. 3 Then, press the Ref softkey again to enable/disable the reference waveform display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 Turn the upper multiplexed knob to adjust the reference waveform scale. 3 Turn the lower multiplexed knob to adjust the reference waveform position. To adjust reference waveform skew Once reference waveforms are displayed, you can adjust their skew. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
You can recall a reference waveform file from a USB storage device into one of the reference waveform locations. See “To recall reference waveform files from a USB storage device" on page 248. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Digital Channels To connect the digital probes to the device under test Acquiring waveforms using the digital channels To display digital channels using AutoScale Interpreting the digital waveform display To switch all digital channels on or off...
You do not need to power- off the oscilloscope. Probe cable for digital channels C A U T I O N Use only the Agilent logic probe and accessory kit supplied with the mixed-signal oscilloscope (see “Accessories Available" on page 294).
Page 93
4 Connect a grabber to one of the probe leads. (Other probe leads are omitted from the figure for clarity.) Grabber 5 Connect the grabber to a node in the circuit you want to test. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 94
Signal Ground Grabber 7 Repeat these steps until you have connected all points of interest. Signals Ground Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
When signals are connected to the digital channels — be sure to connect the ground leads — AutoScale quickly configures and displays the digital channels. • To configure the instrument quickly, press the [AutoScale] key. Figure 11 Example: AutoScale of digital channels (MSO models only) Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
“How AutoScale Works" page 29. To set the instrument to the factory- default configuration, press the [Default Setup] key. Interpreting the digital waveform display The following figure shows a typical display with digital channels. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
To change the displayed size of the digital channels 1 Press the [Digital] key. 2 Press the size ( ) softkey to select how the digital channels are displayed. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Each time you press the softkey, the softkey's mode toggles between Turn on and Turn off. To change the logic threshold for digital channels 1 Press the [Digital] key so that the Digital Channel Menu is displayed. 2 Press the Thresholds softkey Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Dnn designation (where nn is a one or two digit channel number) to D*. The "*" indicates that two channels are overlaid. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
“Using cursors to read bus values" on page 101). The Base softkey lets you choose to display the bus values in hex or binary. The buses are shown at the bottom of the display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 101
3 Press the Source softkey and select Bus1 or Bus2. 4 Use the Entry knob and the X1 and X2 softkeys to position the cursors where you want to read the bus values. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 102
— rising edge ( ) or falling edge ( ) — are included in the pattern specification. A byte that consists of all don't cares (X) will be displayed in the bus as a don't care (X). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The design of the probes minimizes the first problem, while the second is easily addressed by good probing practices. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
This high- frequency model takes into account pure tip capacitance to ground as well as series tip resistance, and the cable's characteristic impedance (Z Figure 12 DC and Low-Frequency Probe Equivalent Circuit Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 105
The stray tip capacitance, which is generally small (1 pF), sets the final break point on the impedance chart. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Increased length in this path will, at high frequencies, create large common mode voltages at the probe input. The voltage generated behaves as if this path were an inductor according to the equation: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 107
LC circuit at the input of the probe, is also increased. Because the digital channels display reconstructed waveforms, they do not show ringing and perturbations. You will not find ground problems through examination of the waveform display. In fact, it is likely Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
If you need to remove a probe lead from the cable, insert a paper clip or other small pointed object into the side of the cable assembly, and push to release the latch while pulling out the probe lead. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 109
Replacement 2-inch probe grounds (qty 5) 5959-9335 Replacement pod ground leads (qty 5) 5090-4833 Grabbers (qty 20) 01650-94309 Package of probe labels For other replacement parts, consult the InfiniiVision 2000/3000 X- Series Oscilloscopes Service Guide. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The threshold level for each serial signal can be set in the Signals Menu. Press the [Serial] key, then the Signals softkey. Serial Decode Options Agilent's hardware- accelerated serial decode options can be installed when the oscilloscope is manufactured, or added later. The following serial decode licenses are available: •...
268. To order serial decode licenses, go to "www.agilent.com" and search for the product number (for example, DSOX3AUTO) or contact your local Agilent Technologies representative (see "www.agilent.com/find/contactus)." Lister Lister is a powerful tool for investigating protocol failures. You can use Lister to view large amounts of packet level serial data in a tabular format, including time tags and specific decoded values.
Page 113
Lister row and automatically set the horizontal scale setting. 7 Press the Undo Zoom softkey to return to the horizontal scale and delay settings before the last Zoom to Selection. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The Search softkey lets you specify events to find. It is similar to specifying protocol triggers. Events found are marked in orange in the far left Lister column. The total number of events found is displayed above the softkeys. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 115
“Searching for SPI Data in the Lister" on page 342 if you have Option LSS (or the DSOX3EMBD upgrade). • “Searching for UART/RS232 Data in the Lister" on page 363 if you have Option 232 (or the DSOX3COMP upgrade). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Display Settings To adjust waveform intensity To set or clear persistence To clear the display To adjust the grid brightness To freeze the display To adjust waveform intensity You can adjust the intensity of displayed waveforms to account for various signal characteristics, such as fast time/div settings and low trigger rates.
When variable persistence is selected, press the Time softkey and use the Entry knob to specify the amount of time that previous acquisitions are to be displayed. The display will begin accumulating multiple acquisitions. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Each major horizontal division in the grid corresponds to the time/div shown in the status line at the top of the display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 To un- freeze the display, press [Quick Action] again. Manual cursors can be used on the frozen display. Many activities, such as adjusting the trigger level, adjusting vertical or horizontal settings, or saving data will un- freeze the display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Labels To turn the label display on or off To assign a predefined label to a channel To define a new label To load a list of labels from a text file you create...
To assign a predefined label to a channel 1 Press the [Label] key. 2 Press the Channel softkey, then turn the Entry knob or successively press the Channel softkey to select a channel for label assignment. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The channel does not have to be turned on to have a label assigned to it. If the channel is turned on, its current label will be highlighted. 3 Press the Spell softkey; then, turn the Entry knob to select the first character in the new label. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Use a text editor to create each label. Each label can be up to ten characters in length. Separate each label with a line feed. 2 Name the file labellist.txt and save it on a USB mass storage device such as a thumb drive. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Defaulting labels without erasing the default library N O T E Pressing [Default Setup] sets all channel labels back to the default labels but does not erase the list of user-defined labels in the library. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Triggers Adjusting the Trigger Level Forcing a Trigger Edge Trigger Pulse Width Trigger Pattern Trigger Rise/Fall Time Trigger Nth Edge Burst Trigger Runt Trigger Setup and Hold Trigger Video Trigger USB Trigger Serial Trigger A trigger setup tells the oscilloscope when to acquire and display data.
Page 130
(horizontal position) setting (see “To adjust the horizontal delay (position)" on page 47). Trigger Event Post-Trigger Buffer Pre-Trigger Buffer Acquisition Memory Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Trigger] to force a trigger and see what the input signals look like. In the Auto trigger mode, when the trigger condition is not met, triggers are forced and the "Auto?" indicator is displayed. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
W = Waveform generator. • 4 Press the Slope softkey and select rising edge, falling edge, alternating edges, or either edge. The selected slope is displayed in the upper- right corner of the display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 133
You can then pan and zoom through the data using the Horizontal and Vertical knobs to find a stable trigger point. AutoScale often produces a triggered display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The source can be any analog or digital channel available on your oscilloscope. 4 Adjust the trigger level: • For analog channels, turn the Trigger Level knob. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 135
For example, for a positive pulse, if you set t>10 ns: Trigger 10 ns 10 ns • Within a range of time values (><). For example, for a positive pulse, if you set t>10 ns and t<15 ns: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Pattern. 3 Press the Qualifier softkey; then, turn the Entry knob to select from the pattern duration qualifier options: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 137
5 For each channel you select, press the Pattern softkey; then, turn the Entry knob to set the condition for that channel in the pattern. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 138
If no edge is specified, the oscilloscope will trigger on the last edge that makes the pattern true. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
0 or 1, the "$" sign will be displayed for the digit. For information regarding digital bus display when Pattern triggering see “Bus values are displayed when using Pattern trigger" on page 102. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Rise/Fall Time. 3 Press the Source softkey, and turn the Entry knob to select the input channel source. 4 Press the Rising Edge or Falling Edge softkey to toggle between edge types. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
6 Press the Edge softkey; then, turn the Entry knob to which edge number to trigger on. Runt Trigger The Runt trigger looks for pulses that cross one threshold but not another. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 143
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Runt. 3 Press the Source softkey, and turn the Entry knob to select the input channel source. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
To trigger on setup & hold violations: 1 Press the [Trigger] key. 2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Setup and Hold. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 145
Level knob. 8 Press the < Setup softkey, and turn the Entry knob to select the setup time. 9 Press the < Hold softkey, and turn the Entry knob to select the hold time. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The oscilloscope is sensitive to this and will not trigger if the probe is not properly compensated, especially for progressive formats. 1 Press the [Trigger] key. 2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Video. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 147
N O T E Many video signals are produced from 75 sources. To provide correct matching to these sources, a 75 terminator (such as an Agilent 11094B) should be connected to the oscilloscope input. 4 Press the sync polarity softkey to set the Video trigger to either positive ) or negative ( ) sync polarity.
Page 148
“To trigger on a specific line of video" on page 149 • “To trigger on all sync pulses" on page 150 • “To trigger on a specific field of the video signal" on page 151 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Field 1 and Field 2. This is a quick way to compare the Field 1 VITS and Field 2 VITS or to check for the correct insertion of the half line at the end of Field 1. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Video. 3 Press the Settings softkey, then press the Standard softkey to select the appropriate TV standard. 4 Press the Mode softkey and select All Lines. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Video. 3 Press the Settings softkey, then press the Standard softkey to select the appropriate TV standard. 4 Press the Mode softkey and select Field1 or Field2. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select Video. 3 Press the Settings softkey, then press the Standard softkey to select the appropriate TV standard. 4 Press the Mode softkey and select All Fields. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
But this definition of field does not take into consideration the phase of the reference subcarrier. When Field 1 is selected, the trigger system will find any field where the vertical sync Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 154
Repeat until the correct phase is displayed. When holdoff is adjusted using the Field Holdoff softkey and the Entry knob, the corresponding holdoff time will be displayed in the Trigger Mode and Coupling Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Reset Complete (RC), Enter Suspend (Suspend), or Exit Suspend (Exit Sus) on the differential USB data lines (D+ and D- ). USB Low Speed and Full Speed are supported by this trigger. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 156
SOP (Start of Packet) — triggers at the Sync bit at the beginning of the packet. • EOP (End of Packet) — triggers at the end of the SE0 portion of the EOP. RC (Reset Complete) — triggers when SE0 is > 10 ms. • Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
309 if you have Option AMS (or the DSOX3AUTO upgrade). • “I2C Triggering" on page 326 if you have Option LSS (or the DSOX3EMBD upgrade). • “I2S Triggering" on page 348 if you have Option SND (or the DSOX3AUDIO upgrade). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 158
317 if you have Option AMS (or the DSOX3AUTO upgrade). • “SPI Triggering" on page 337 if you have Option LSS (or the DSOX3EMBD upgrade). • “UART/RS232 Triggering" on page 357 if you have Option 232 (or the DSOX3COMP upgrade). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Trigger Mode/Coupling To select the Auto or Normal trigger mode To select the trigger coupling To enable or disable trigger noise rejection To enable or disable trigger HF Reject To set the trigger holdoff...
This may be more likely, for example, when the horizontal scale knob is set to a slow time/div setting, such as 500 ms/div. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 161
Trig'd? to flash (this tells you the pre- trigger buffer is filled). See Also • “Forcing a Trigger" on page 131 • “To set the trigger holdoff" on page 164 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Use LF Reject coupling to get a stable edge trigger when your waveform has low frequency noise. TV coupling — is normally grayed- out, but is automatically selected • when TV trigger is enabled in the Trigger Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Press the [Mode/Coupling] key. 2 In the Trigger Mode and Coupling Menu, press the HF Reject softkey to enable or disable. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Changing the time base settings does not affect the trigger holdoff time. With Agilent's MegaZoom technology, you can press [Stop], then pan and zoom through the data to find where the waveform repeats. Measure this time using cursors;...
4 Press the Probe softkey; then, turn the entry knob to specify the probe attenuation. The attenuation factor can be set from 0.1:1 to 1000:1 in a 1- 2- 5 sequence. The probe attenuation factor must be set properly for measurements to be made correctly. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Acquisition Control Running, Stopping, and Making Single Acquisitions (Run Control) Overview of Sampling Selecting the Acquisition Mode Acquiring to Segmented Memory This chapter shows how to use the oscilloscope's acquisition and run controls.
Page 168
To acquire data with the longest possible record length, press the [Single] key. For more information on settings that affect record length, see “Length Control" on page 243. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Aliasing Aliasing occurs when signals are under- sampled (f < 2f ). Aliasing is the signal distortion caused by low frequencies falsely reconstructed from an insufficient number of sample points. Figure 24 Aliasing Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
(square waves are made up of sine waves at the fundamental frequency and an infinite number of odd harmonics), and typically, for 1 Ghz bandwidths and below, oscilloscopes have a Gaussian frequency response. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
. This way, there is less aliasing, and aliased frequency components have a greater amount of attenuation. See Also Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity: How to Make the Most Accurate Digital Measurements, Agilent Application Note 1587 ("http://cp.literature.agilent.com/litweb/pdf/5989- 5732EN.pdf")
= 1.0 x f knee = 1.3 x f knee = 1.9 x f knee See Also Choosing an Oscilloscope with the Right Bandwidth for your Application, Agilent Application Note 1588 ("http://cp.literature.agilent.com/litweb/pdf/5989- 5733EN.pdf") Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Press the [Acquire] key on the front panel. 2 In the Acquire Menu, press the Acq Mode softkey; then, turn the Entry knob to select the acquisition mode. The InfiniiVision oscilloscopes have the following acquisition modes: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
4 GSa/s, a sample is taken every 250 ps (sample period). See Also • “Glitch or Narrow Pulse Capture" on page 175 • “Using Peak Detect Mode to Find a Glitch" on page 176 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 175
Normal acquire mode, making them easier to see. To characterize the glitch, use the cursors or the automatic measurement capabilities of the oscilloscope. Figure 27 Sine With Glitch, Normal Mode Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 176
4 Characterize the glitch with Zoom mode: a Press the zoom key (or press the [Horiz] key and then the Zoom softkey). b To obtain a better resolution of the glitch, expand the time base. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 Press the #Avgs softkey and turn the Entry knob to set the number of averages that best eliminates the noise from the displayed waveform. The number of acquisitions being averaged is displayed in the # Avgs softkey. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 178
Acquisition Control Figure 29 Random noise on the displayed waveform Figure 30 128 Averages used to reduce random noise Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Acquiring to Segmented Memory You can purchase the oscilloscope with the segmented memory option factory- installed (Option SGM) or you can install a license to enable it (order model number DSOX3SGM "Segmented Memory"). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 180
If the signal you are measuring has more than about 1 s of inactivity, consider selecting the Normal trigger mode to prevent AutoTriggering. See “To select the Auto or Normal trigger mode" on page 160. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
To perform measurements and view statistical information, press [Meas] and set up your desired measurements (see Chapter 14, “Measurements,” starting on page 193). Then, press Analyze Segments. Statistical data will be accumulated for the measurements you have chosen. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Saving Data from Segmented Memory You can save either the currently displayed segment (Save Segment - Current), or all segments (Save Segment - All) in the following data formats: CSV, ASCII XY, and BIN. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 183
When the oscilloscope is busy saving multiple segments, progress is displayed in the upper right area of the display. For more information, see “To save CSV, ASCII XY, or BIN data files" page 240. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 185
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Cursors To make cursor measurements Cursor Examples Cursors are horizontal and vertical markers that indicate X- axis values (usually time) and Y- axis values (usually voltage) on a selected waveform source. You can use cursors to make custom voltage or time measurements on oscilloscope signals, and timing measurements on digital channels.
The time and voltage positions are shown for the markers. The vertical (Y) and horizontal (X) differences between the markers are shown as X and Y values. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 187
The X1 X2 linked and Y1 Y2 linked selections let you adjust both cursors at the same time, while the delta value remains the same. This can be useful, for example, for checking pulse width variations in a pulse train. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The currently selected cursor(s) display brighter than the other cursors. 6 Adjust the selected cursor(s) by turning the Cursors knob. Cursor Examples Figure 31 Cursors used to measure pulse widths other than middle threshold points Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 189
Cursors Figure 32 Cursors measure frequency of pulse ringing Expand the display with Zoom mode, then characterize the event of interest with the cursors. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 190
Cursors Figure 33 Cursors track Zoom window Put the X1 cursor on one side of a pulse and the X2 cursor on the other side of the pulse. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 191
Cursors Figure 34 Measuring pulse width with cursors Press the X1 X2 linked softkey and move the cursors together to check for pulse width variations in a pulse train. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 192
Cursors Figure 35 Moving the cursors together to check pulse width variations Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 193
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Measurements To make automatic measurements Measurements Summary Voltage Measurements Time Measurements Count Measurements Mixed Measurements Measurement Thresholds Measurement Window with Zoom Display Measurement Statistics The [Meas] key lets you make automatic measurements on waveforms.
"< value", or "> value", or a similar message to indicate that the measurement may not be reliable. 3 Press the Type: softkey; then, rotate the Entry knob to select a measurement to be made. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
All measurements except Counter are available for reference waveforms and math waveforms other than FFT. A limited set of measurements is available for math FFT waveforms and for digital channel waveforms (as described in the following table). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The resultant units are in Hertz. Use the cursors to make other measurements on FFT. Snapshot All The Snapshot All measurement type displays a popup containing a snapshot of all the single waveform measurements. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Probe Units softkey. See “To specify the channel units" page 65. The units of math waveforms are described in “Units for Math Waveforms" on page 86. • “Peak- Peak" on page 199 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The Top of a waveform is the mode (most common value) of the upper part of the waveform, or if the mode is not well defined, the top is the same as Maximum. The Y cursor shows the value being measured. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The Base of a waveform is the mode (most common value) of the lower part of the waveform, or if the mode is not well defined, the base is the same as Minimum. The Y cursor shows the value being measured. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Maximum − D Top Rising edge overshοot = × 100 Amplitude Falling edge overshοot = Base − D local Minimum × 100 Amplitude Overshoot local Maximum Base local Minimum Overshoot Figure 37 Automatic Overshoot measurement Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The N Cycles measurement interval variation measures the value on an integral number of periods of the displayed signal. If less than three edges are present, the measurement shows "No edges". The X cursors show what interval of the waveform is being measured. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The standard deviation of a measurement is the amount that a measurement varies from the mean value. The Mean value of a measurement is the statistical average of the measurement. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 204
• N = the number of measurements taken. • x = the ith measurement result. The standard deviation is calculated as follows: ∑ − ¯ where: • = the standard deviation. • N = the number of measurements taken. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
You may need to change the measurement window setting so that the measurement is made in the lower, Zoom window. See “Measurement Window with Zoom Display" on page 216. If the waveform is clipped, it may not be possible to make the measurement. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The Y cursor shows the threshold level used in the measurement. Analog and digital channels can be selected as the source. Only one Counter measurement can be displayed at a time. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The X cursors show the time period being measured. The Y cursor shows the middle threshold point. Duty cycle = + Width Period × 100 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
4 Press the Settings softkey to select the second analog channel source and slope for the delay measurement. The default Delay settings measure from the rising edge of channel 1 to the rising edge of channel 2. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Minimum, starting from the left- side of the display. For periodic signals, the position of the minimum may vary throughout the waveform. The X cursor shows where the current X at Min Y value is being measured. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
This measurement is available for analog channels. Mixed Measurements • “Area" on page 213 Area Area measures the area between the waveform and the ground level. Area below the ground level is subtracted from area above the ground level. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
You can also open the Measurement Threshold Menu by pressing [Analyze] > Features and then selecting Measurement Thresholds. 2 Press the Source softkey to select the analog channel or math waveform source for which you want to change measurement thresholds. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 215
The middle value is bounded by the values set for lower and upper thresholds. The default middle threshold is 50% or 1.20 V. If threshold Type is set to %, the middle threshold value can be set • from 6% to 94%. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1. Select the measurements you desire for the channels you are using (see “Measurements Summary" on page 195). From the Measurement Menu, press the Statistics softkey to enter the Statistics Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 217
When you navigate away from the Measurements Menu, the statistics display will no longer be displayed, but statistical data collection will continue. Return to the Measurements Menu to see the data again. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 218
Segments softkey to accumulate measurement statistics for the acquired segments. You can also turn on infinite persistence (in the Display Menu) and press the Analyze Segments softkey to create an infinite persistence display. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Mask Testing To create a mask from a "golden" waveform (Automask) Mask Test Setup Options Mask Statistics To manually modify a mask file Building a Mask File One way to verify a waveform's compliance to a particular set of parameters is to use mask testing.
Page 220
(volts or seconds), selectable using the Units softkey. 8 Press the Create Mask softkey. The mask is created and testing begins. Whenever the Create Mask softkey is pressed the old mask is erased and a new mask is created. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
± Y and ± X settings. They may be set so large that the mask is not visible. Mask Test Setup Options From the Mask Test Menu, press the Setup softkey to enter the Mask Setup Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 222
(which is tied to the amount of failures per test). The sigma value may exceed the selected value when a small sigma value is chosen. The actual sigma is displayed. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 223
The Source softkey in the Mask Setup Menu is the same as the Source softkey in the Automask Menu. Test All When enabled, all displayed analog channels are included in the mask test. When disabled, just the selected source channel is included in the test. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• Number of failures (acquisitions in which the signal excursion went beyond the mask). • Failure rate (percentage of failures). • Sigma (the ratio of process sigma to maximum achievable sigma, based on number of waveforms tested). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
9 Open the .msk file your created using a text editor (such as Wordpad). 10 Edit, save, and close the file. The mask file contains the following sections: • Mask File Identifier. • Mask Title. • Mask Violation Regions. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 226
"MIN" for the first and last points. The top region must be the lowest numbered region in the file. The bottom region must be the highest numbered region in the file. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 227
The oscilloscope setup information contains remote programming language commands that the oscilloscope executes when the mask file is loaded. Any legal remote programming command can be entered in this section. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
X and Y values in the mask file. The following mask file produced the mask shown above: MASK_FILE_548XX "All Regions" /* Region Number */ 1 /* Number of vertices */ 4 -12.50, -10.00, 1.750 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 229
/* Number of vertices */ 5 10.00, -1.000 12.50, -0.500 15.00, -0.500 15.00, -1.500 12.50, -1.500 /* Region Number */ 8 /* Number of vertices */ 4 -12.50, -10.00, -1.750 10.00, -1.750 12.50, setup :MTES:ENAB 1 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The number of acquisitions tested is also logged and displayed as "# of Tests". The mask file allows greater resolution than the 200 X 640 database. Some quantization of data occurs to reduce the mask file data for display on- screen. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Waveform Generator To select generated waveform types and settings To output the waveform generator sync pulse To specify the waveform generator output load To use waveform generator logic presets To restore waveform generator defaults A waveform generator is built into the oscilloscope.
Page 232
2 In the Waveform Generator Menu, press the Waveform softkey and turn the Entry knob to select the waveform type. 3 Depending on the selected waveform type, use the remaining softkeys and the Entry knob to set the waveform's characteristics. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 233
Or, you can choose to enter frequency values or period values. Keep pressing the softkey to select the type of adjustment. Turn the Entry knob to adjust the value. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Sine, Ramp, The Sync signal is a square waveform with a 50% duty cycle. Pulse Square The Sync signal is a square waveform with the same duty cycle as the main output. Noise Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
3 In the Waveform Generator Settings Menu, press the Logic Presets softkey. 4 In the Waveform Generator Logic Level Presets Menu, press one of the softkeys to set the generated signal's Low and High voltages to logic compatible levels: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
3 In the Waveform Generator Settings Menu, press the Default Wave Gen softkey. The waveform generator factory default settings (1 kHz sine wave, 500 mVpp, 0 V offset, High- Z output load) are restored. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
PNG formats. Acquired waveform data can be saved to a USB storage device in comma- separated value (CSV), ASCII XY, binary (BIN), and Agilent logic analyzer binary (ALB) formats. There is also a command to securely erase all the oscilloscope's non- volatile internal memory.
Page 238
“To save reference waveform files to a USB storage device" on page 245. ALB data (*.alb) — This creates an Agilent proprietary format file that • can be imported by the Agilent Logic Analyzer application software, using the Agilent B4610A Data Import tool, for offline viewing and analysis.
270. To save setup files Setup files can be saved to one of 10 internal (\Agilent Flash) locations or to an external USB storage device. 1 Press [Save/Recall] > Save > Format; then, turn the Entry knob to select Setup (*.scp).
CSV data (*.csv), ASCII XY data (*.csv), or Binary data (*.bin). 2 Press the softkey in the second position and use the Entry knob to navigate to the save location. See “To navigate storage locations" page 246. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
304 To save ALB data files Agilent logic analyzer binary (ALB) format data files can be viewed and analyzed offline on a PC using the Agilent Logic Analyzer application and the Agilent B4610A Data Import Tool. See the "Agilent Technologies...
Page 242
1 or If you connect your serial bus signals to the oscilloscope as shown in the following table, the bus/signal names in the Agilent Logic Analyzer application will be correct. Otherwise, you must re- map the signals in the Agilent Logic Analyzer application.
ALB format files. It sets the number of data points that will be output to the file. Only displayed data points are saved. The maximum number of data points depends on these things: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 244
ASCII XY medium slowest See Also • “Binary Data (.bin) Format" on page 296 • “CSV and ASCII XY files" on page 303 • “Minimum and Maximum Values in CSV Files" on page 304 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
A message indicating whether the save was successful is displayed. To save masks Mask files can be saved to one of four internal (\Agilent Flash) locations or to an external USB storage device. 1 Press [Save/Recall] > Save > Format; then, turn the Entry knob to select Mask (*.msk).
• The proposed file name is shown in the Save to file = line above the softkeys. • To overwrite an existing file, browse to that file and select it. To create a new file name, see “To enter file names" on page 247. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
“To recall reference waveform files from a USB storage device" on page 248. You can also recall setups and mask files by loading them using the File Explorer. See “File Explorer" on page 259. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
270. To recall setup files Setup files can be recalled from one of 10 internal (\Agilent Flash) locations or from an external USB storage device. 1 Press [Save/Recall] > Recall > Recall:; then, turn the Entry knob to select Setup (*.scp).
You must confirm the recall because there are no user settings that are left unchanged. Performing a Secure Erase 1 Press the [Save/Recall] key. 2 In the Save/Recall Menu, press Default/Erase. 3 In the Default menu, press Secure Erase. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 250
This performs a secure erase of all non- volatile memory in compliance with National Industrial Security Program Operation Manual (NISPOM) Chapter 8 requirements. You must confirm the secure erase, and the oscilloscope will reboot when finished. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Print (Screens) To print the oscilloscope's display To set up network printer connections To specify the print options To specify the palette option You can print the complete display, including the status line and softkeys, to a USB printer or a network printer when the DSOXLAN LAN/VGA module is installed.
1 Press the [Print] key on the front panel. 2 In the Print Configuration Menu, press the Print to softkey; then, turn the Entry knob to select the network printer you want to configure (either #0 or #1). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
In the Print Configuration Menu, press the Options softkey to change the following options: • Setup Information — Select this to print oscilloscope setup information on your printout, including vertical, horizontal, trigger, acquisition, math, and display settings. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The oscilloscope's print driver cannot print color images to color laser printers, so the Color option is not available when connected to laser printers. • Grayscale — Select this to print the screen in shades of gray rather than in color. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide Utility Settings I/O Interface Settings Setting up the Oscilloscope's LAN Connection File Explorer Setting Oscilloscope Preferences Setting the Oscilloscope's Clock Setting the Rear Panel TRIG OUT Source Performing Service Tasks Configuring the [Quick Action] Key This chapter explains oscilloscope utility functions.
When you connect the oscilloscope to a LAN it is a good practice to limit access to the N O T E oscilloscope by setting a password. By default, the oscilloscope is not password protected. “Setting a Password" on page 283 to set a password. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 Press [Utility] > I/O. 3 Press the LAN Settings softkey. 4 Press the Config softkey; then, turn the Entry knob to select Automatic, and press the softkey again to disable it. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
LAN configuration settings 4 Connect your PC to the oscilloscope using a cross- over LAN cable such as Agilent part number 5061- 0701, available on the web at "www.parts.agilent.com". 5 Cycle power on the oscilloscope. Wait until the LAN connection is configured: Press [Utility] >...
The square receptacle on the rear panel labeled "DEVICE" is provided for controlling the oscilloscope over USB. See the Programmer's Guide for more information. The oscilloscope's internal file system, under "\Agilent Flash", consists of 10 locations for oscilloscope setup files, and four locations for mask files.
Page 260
When the USB mass storage device is connected to the oscilloscope's front or rear USB host port, a small four- color circle icon may be displayed briefly as the USB device is read. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The ground level of the signal is identified by the position of the ground level ( ) icon at the far- left side of the display. The ground level will not move when you adjust the vertical sensitivity (volts/division) control. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Use the Entry knob to choose a character. Then press the Enter softkey to advance to the next character and repeat the process. The resultant string is displayed in the "Text =" line above the softkeys. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Press the Acq Mode softkey and turn the Entry knob to select whether • the acquisition mode should be preserved during autoscale: Normal — to make the oscilloscope switch to Normal acquisition • mode whenever the [AutoScale] key is pressed. This is the default mode. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
TRIG OUT.The rising edge is delayed 30 ns from the oscilloscope's trigger point. The output level is 0- 5 V into an open circuit, and 0- 2.5 V into 50 . See Chapter 10, “Triggers,” starting on page 129. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
“To display oscilloscope information" on page 268 • “To display the user calibration status" on page 269 For other information related to oscilloscope maintenance and service, see: • “To clean the oscilloscope" on page 269 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Performing User Cal will invalidate your Certificate of Calibration. If NIST (National Institute of Standards and Technology) traceability is required, perform the "Performance Verification" procedure in the Agilent InfiniiVision 2000/3000 X- Series Oscilloscopes Service Guide using traceable sources. To perform user calibration:...
Page 267
Then connect a BNC(f)- to- BNC(f) (barrel connector) to the tee as shown below. To Channel 1 To Channel 2 To Channel 3 Longer cable to TRIG OUT To Channel 4 Figure 40 User Calibration cable for 4-channel oscilloscope Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Press [Help] > About Oscilloscope to display information about your oscilloscope: • Model number. • Serial number. • Bandwidth. • Module installed. • Software version. • Installed licenses. See also “Loading Licenses and Displaying License Information" on page 295. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
If the system cannot find your product's warranty status, select Contact Us and speak with an Agilent Technologies representative. To contact Agilent Information on contacting Agilent Technologies can be found at: "www.agilent.com/find/contactus" Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Utility Settings To return the instrument Before shipping the oscilloscope to Agilent Technologies, contact your nearest Agilent Technologies sales or service office for additional details. Information on contacting Agilent Technologies can be found at: "www.agilent.com/find/contactus" 1 Write the following information on a tag and attach it to the oscilloscope.
Page 271
160. Quick Clear Display — clears the display, see • “To clear the display" page 120. Once the [Quick Action] key is configured, you simply press it to perform the selected action. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 273
Identification Function Instrument Utilities Setting a Password When the Agilent InfiniiVision X- Series oscilloscopes have the DSOXLAN LAN/VGA option module installed, you can access the oscilloscope's built- in web server using a Java- enabled web browser. The oscilloscope's web interface lets you: •...
It is possible to use a point- to- point connection, but using a normal LAN connection is the preferred method. 2 Type the oscilloscope's hostname or IP address in the web browser. The oscilloscope's web interface Welcome Page is displayed. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
If Java is not installed on your PC, you will be prompted to install the Sun Microsystems N O T E Java Plug-in. This plug-in must be installed on the controlling PC for the web interface's Remote Front Panel or Remote Programming operations. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The SCPI Command window is useful for testing commands or entering a few commands interactively. When creating automated programs for controlling the oscilloscope, you will typically use the Agilent IO Libraries from within a programming environment like Microsoft Visual Studio (see “Remote Programming with Agilent IO Libraries"...
274). 2 When the oscilloscope's web interface is displayed, select Browser Web Control, then select Remote Programming. 3 On the Remote Programming page, click SCPI Commands..The SCPI Commands applet window appears. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
While the SCPI Commands applet window lets you enter and remote programming commands, remote programming for automated test and data acquisition is typically done using the Agilent IO Libraries, which are separate from the instrument's web interface. The Agilent IO Libraries let a controller PC communicate with Agilent...
Web Interface The Agilent IO Libraries Suite connectivity software to enables communication over these interfaces. You can download the Agilent IO Libraries Suite from "www.agilent.com/find/iolib". Information about controlling the oscilloscope through remote commands is contained in the Programmer's Guide, which is included on the documentation CD supplied with this oscilloscope.
1 Access the oscilloscope's web interface (see “Accessing the Web Interface" on page 274). 2 When the oscilloscope's web interface is displayed, select the Save/Recall tab from the left side of the Welcome screen. 3 Click the Recall link. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
3 Right- click on the image and select Save Picture As... (or Print Picture...). 4 Select a storage location for the image file and click Save. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
An "Identify" message is displayed on the oscilloscope; you can either select Identification off or press the OK softkey on the oscilloscope to continue. Identification option Instrument Utilities The Instrument Utilities page of the web interface lets you: • View installed options. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Web browser and changing parameters. Remote users can still view the Welcome screen, view network status, etc., but they can't operate the instrument or change its setup without the password. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 284
2 When the oscilloscope's web interface is displayed, select the Configure Network tab from the instrument's Welcome page. 3 Click the Modify Configuration button. Modify Configuration Configure Network 4 Enter your desired password, and click Apply Changes. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 285
• Using the keys on the front panel of the oscilloscope, press [Utility] > I/O > LAN Reset. • Using the web browser select the Configure Network tab, select Modify Configuration, erase the Password, and select Apply Changes. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Or, go to the Agilent home page at "www.agilent.com" and search for "3000 X- Series oscilloscopes data sheet". To order a data sheet by phone, please contact your local Agilent office. The complete list is available at: "www.agilent.com/find/contactus". Measurement Category •...
Measurement category IV is for measurements performed at the source of the low- voltage installation. Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
This product is intended to be powered by MAINS that comply to Overvoltage Category Category II, which is typical of cord-and-plug connected equipment. Pollution Degree The InfiniiVision 2000/3000 X-Series oscilloscopes may be operated in environments of Pollution Degree 2 (or Pollution Degree 1). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• “Accessories Available" on page 294 AutoProbe Most Agilent single- ended active, differential, and current probes are Interface compatible with the AutoProbe interface. Active probes that do not have their own external power supply require substantial power from the AutoProbe interface.
These probes have a pin on their connector that connects to the ring around the oscilloscope's BNC connector. Therefore, the oscilloscope will automatically set the attenuation factor for recognized Agilent passive probes. Passive probes that do not have a pin that connects to the ring around the BNC connector will not be recognized by the oscilloscope, and you must set the probe attenuation factor manually.
Current probe, 50 MHz, 30 A, AC/DC (use with N2779A power supply) N2783A Current probe, 100 MHz, 30 A, AC/DC (use with N2779A power supply) N2893A Current probe, 100 MHz, 15 A, AC/DC with AutoProbe interface “AutoProbe Interface" on page 290. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
292), and current probes (“Current Probes" on page 293), the following accessories are available for the InfiniiVision 3000 X- Series oscilloscopes. Table 10 Accessories Available for InfiniiVision 3000 X-Series Oscilloscopes Model/Part # Description DSOXLAN LAN/VGA connection module DSOXGPIB...
Segmented Memory. Order DSOX3SGM. Lets you capture infrequent or burst signals with great resolution by eliminating the capture of your signal's "inactivity". Audio Serial Triggering and Analysis (I2S). Order DSOX3AUDIO. Waveform Generator. Order DSOX3WAVEGEN. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent Technologies representative or see "www.agilent.com/find/3000X- Series". Software and Firmware Updates From time to time Agilent Technologies releases software and firmware updates for its products. To search for firmware updates for your oscilloscope, direct your web browser to "www.agilent.com/find/3000X- Series- sw".
Agilent Technologies web site at "www.agilent.com/find/3000X- Series- sw". Agilent provides the .m files, which need to be copied into the work directory for MATLAB. The default work directory is C:\MATLAB7\work. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
There is only one file header in a binary file. The file header consists of the following information. Cookie Two byte characters, AG, that indicate the file is in the Agilent Binary Data file format. Version Two bytes that represent the file version.
Page 299
A 64-bit double, only used when saving multiple segments (requires segmented memory option). This is the time (in seconds) since the first trigger. Segment Index A 32-bit unsigned integer. This is the segment number. Only used when saving multiple segments. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
"Example Program for Reading Binary Data". Examples of Binary Files Single The following picture shows a binary file of a single acquisition with Acquisition multiple analog channels. Multiple Analog Channels Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 301
Bytes per Point = 4 12 bytes Voltage Data N buffer size Single The following picture shows a binary file of a single acquisition with all Acquisition All pods for the logic channels saved. Pods Logic Channels Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 302
Bytes per Point = 1 12 bytes Pod 2 Timing Data buffer size Segmented The following picture shows a binary file of a segmented memory Memory acquisition on one analog channel. Acquisition on One Analog Channel Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
12 bytes Voltage Data N buffer size CSV and ASCII XY files • “CSV and ASCII XY file structure" on page 304 • “Minimum and Maximum Values in CSV Files" on page 304 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
CSV record is configured to provide a best- estimate of all the samples that each point in the record represents. Therefore, the min and max values may not appear in the CSV file. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
GNU General Public License for more details. The license is located on the Agilent InfiniiVision Oscilloscopes Documentation CD- ROM. RealVNC source code can be obtained from RealVNC or by contacting Agilent. Agilent will charge for the cost of physically performing the source distribution. HDF5 Reference Waveform files use HDF5.
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide CAN/LIN Triggering and Serial Decode Setup for CAN Signals CAN Triggering CAN Serial Decode Setup for LIN Signals LIN Triggering LIN Serial Decode CAN/LIN triggering and serial decode requires Option AMS or the DSOX3AUTO upgrade.
Page 308
9 Press the Sample Point softkey; then, turn the Entry knob to select the point between phase segments 1 and 2 where the state of the bus is measured. This controls the point within the bit's time where the bit value is captured. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
“Setup for CAN Signals" on page 307. The Controller Area Network (CAN) trigger allows triggering on CAN version 2.0A and 2.0B signals. A CAN message frame in CAN_L signal type is shown below: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 310
Overload Frame — The oscilloscope will trigger on CAN overload • frames. 4 If you select a condition that lets you trigger on ID or data values, use the Bits softkey and the CAN Bits Menu to specify those values. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 If the decode line does not appear on the display, press the [Serial] key to turn it on. 3 If the oscilloscope is stopped, press the [Run/Stop] key to acquire and decode data. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• Frame ID appears in hex digits in yellow. Frames of 11 or 29 bits are automatically detected. • Remote frame (RMT) appears in green. • Data length code (DLC) appears in blue for data frames and green for remote frames. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Reset CAN Counters softkey. Types of Frames • Active error frames are CAN frames in which a CAN node recognizes an error condition during a data or remote frame and issues an active error flag. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
ERR counter will be incremented. If a data frame contains an error that is not an active error it is considered a partial frame and no counters are incremented. Interpreting CAN Lister Data Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Error Frame — Finds CAN active error frames. • All Errors — Finds any form error or active error. • Overload Frame — Finds CAN overload frames. • Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
8 Press the Baud Rate softkey to open the LIN Baud Rate Menu. 9 Press the Baud softkey; then, turn the Entry knob to select the baud rate that matches match your LIN bus signal. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
LIN triggering can trigger on the rising edge at the Sync Break exit of the LIN single- wire bus signal (that marks the beginning of the message frame), the Frame ID, or the Frame ID and Data. A LIN signal message frame is shown below: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 318
Note that you can enter a "don't care" value for the frame ID and trigger on data values only. • To set up the number of data bytes and enter their values (in hexadecimal or binary), press the Bits softkey to open the LIN Bits Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Signals" on page 316. For LIN triggering setup see “LIN Triggering" on page 317. N O T E To set up LIN serial decode: 1 Press [Serial] to display the Serial Decode Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 320
You can use the horizontal Zoom window for easier navigation of the decoded data. See Also • “Interpreting LIN Decode" on page 321 • “Interpreting LIN Lister Data" on page 322 • “Searching for LIN Data in the Lister" on page 323 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Scroll or expand the horizontal scale to view the information. • Unknown bus values (undefined or error conditions) are drawn in red. • If there is an error in the synch field, SYNC will appear in red. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• Checksum — (LIN 1.3 only). • Data and Checksum — (LIN 2.0 only). • Errors — highlighted in red. Aliased data is highlighted in pink. When this happens, decrease the horizontal time/div setting and run again. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Errors — Finds all errors. • For more information on searching data, see “Searching Lister Data" page 114. For more information on using the [Navigate] key and controls, see “Navigating the Time Base" on page 56. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 324
CAN/LIN Triggering and Serial Decode Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide I2C/SPI Triggering and Serial Decode Setup for I2C Signals I2C Triggering I2C Serial Decode Setup for SPI Signals SPI Triggering SPI Serial Decode I2C/SPI triggering and serial decode requires Option LSS or the DSOX3EMBD upgrade.
EEPROM data read, or on a read/write frame with a specific device address and data value. 1 Press [Trigger]; then, select the I2C trigger type. 2 Press [Trigger]. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 327
Data is softkey. When this event occurs, the oscilloscope will trigger on the clock edge for the Ack bit after the data byte. This data byte does not need to occur directly after the control byte. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 328
26th clock edge if all bits in the pattern match. The frame is in the format: Frame (Start: Address byte 1: Write: Address byte 2: Ack: Data) For triggering purposes, a restart is treated as a start condition. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 329
8- bit data pattern on which to trigger. You can select a data value in the range of 0x00 to 0xFF (hexadecimal). The oscilloscope will trigger after the start, address, read/write, acknowledge, and data events occur. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
3 If the decode line does not appear on the display, press the [Serial] key to turn it on. 4 If the oscilloscope is stopped, press the [Run/Stop] key to acquire and decode data. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
• Address values appear at the start of a frame. • Write addresses appear in light- blue along with the "W" character. • Read addresses appear in yellow along with the "R" character. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
In addition to the standard Time column, the I2C Lister contains these columns: • Restart — indicated with an "X". • Address — colored blue for writes, yellow for reads. • Data — data bytes. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
26th clock edge if all bits in the pattern match. For more information on searching data, see “Searching Lister Data" page 114. For more information on using the [Navigate] key and controls, see “Navigating the Time Base" on page 56. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Press the slope softkey ( ) to select rising edge or falling edge for the selected Clock source. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 335
Press the Threshold softkey; then, turn the Entry knob to select the MISO signal threshold voltage level. The threshold voltage level is used in decoding, and it will become the trigger level when the trigger type is set to the selected serial decode slot. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 336
The framing signal must be valid for the entire data pattern. If the framing signal is set to Timeout, the oscilloscope generates • it's own internal framing signal after it sees inactivity on the serial clock line. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Press [Trigger]. 2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select the serial slot (Serial 1 or Serial 2) on which the SPI signals are being decoded. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 338
As you rotate the Entry knob, the bit is highlighted in the Data string shown in the waveform area. b Press the 0 1 X softkey to set the bit selected in the Bit softkey to 0 (low), 1 (high), or X (don't care). Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Signals" on page 334. For SPI triggering setup see “SPI Triggering" on page 337. N O T E To set up SPI serial decode: 1 Press [Serial] to display the Serial Decode Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 340
You can use the horizontal Zoom window for easier navigation of the acquired data. See Also • “Interpreting SPI Decode" on page 341 • “Interpreting SPI Lister Data" on page 342 • “Searching for SPI Data in the Lister" on page 342 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Scroll or expand the horizontal scale to view the information. • Aliased bus values (undersampled or indeterminate) are drawn in pink. • Unknown bus values (undefined or error conditions) are drawn in red. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
(Serial 1 or Serial 2) on which the SPI signals are being decoded. 3 Press Search; then, select from these options: • Master-Out, Slave-In (MOSI) Data — for searching MOSI data. • Master-In, Slave-Out (MISO) Data — for searching MISO data. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 343
For more information on searching data, see “Searching Lister Data" page 114. For more information on using the [Navigate] key and controls, see “Navigating the Time Base" on page 56. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 344
I2C/SPI Triggering and Serial Decode Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide I2S Triggering and Serial Decode Setup for I2S Signals I2S Triggering I2S Serial Decode I2S triggering and serial decode requires Option SND or the DSOX3AUDIO upgrade. Only one I2S serial bus can be decoded at a time.
Page 346
(from 4 to 32 bits). 11 Press the Alignment softkey; then, turn the Entry knob to select the desired alignment of the data signal (SDATA). The on- screen diagram changes with your selection. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 347
WS Low indicates Left or Right channel data. The on- screen diagram changes with your selection. WS Low = Left Channel — Left- channel data corresponds to WS=low; right- channel data corresponds to WS=high. WS Low=Left is the oscilloscope's default WS setting. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
1 Press [Trigger]. 2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to select the serial slot (Serial 1 or Serial 2) on which the I2S signals are being decoded. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 349
2 points shown since there are two instances in which the data increases from a value below (or at) the "Armed" value to a value greater than (or equal to) the specified "Trigger" value. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 350
If the setup does not produce a stable trigger, the I2S signal may be slow enough that the N O T E oscilloscope is AutoTriggering. Press the [Mode/Coupling] key, then press the Mode softkey to set the trigger mode from Auto to Normal. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Auto to Normal. You can use the horizontal Zoom window for easier navigation of the acquired data. See Also • “Interpreting I2S Decode" on page 352 • “Interpreting I2S Lister Data" on page 353 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Scroll or expand the horizontal scale to view the data. • Aliased bus values (undersampled or indeterminate) are drawn in pink. • Unknown bus values (undefined or error conditions) are drawn in red. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
The oscilloscope's search capability lets you search for (and mark) certain types of I2S data in the Lister. You can use the [Navigate] key and controls to navigate through the marked rows. 1 With I2S selected as the serial decode mode, press [Search]. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 354
Errors — finds all errors. • For more information on searching data, see “Searching Lister Data" page 114. For more information on using the [Navigate] key and controls, see “Navigating the Time Base" on page 56. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide UART/RS232 Triggering and Serial Decode Setup for UART/RS232 Signals UART/RS232 Triggering UART/RS232 Serial Decode UART/RS232 triggering and serial decode requires Option 232 or the DSOX3COMP upgrade. Setup for UART/RS232 Signals To set up the oscilloscope to capture UART/RS232 signals, use the Signals...
Page 356
Bit Order — Select whether the most significant bit (MSB) or the least significant bit (LSB) is presented after the start bit in the signal from your device under test. For RS232 select LSB. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Note that the setting of this softkey does not affect the selected base of the decode display. 5 Press the Trigger softkey and set up the desired trigger condition: Rx Start Bit — The oscilloscope triggers when a start bit occurs on Rx. • Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 358
9 If Burst is selected, an idle time (1 µs to 10 s) can be specified so that the oscilloscope will look for a trigger condition only after the idle time has past. Press the Idle softkey and rotate the Entry knob to set an idle time. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Valid ASCII characters are between 0x00 and 0x7F. To display in ASCII you must select at least 7 bits in the Bus Configuration. If ASCII is selected and the data exceeds 0x7F, the data is displayed in hex. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 360
See Also • “Interpreting UART/RS232 Decode" on page 361 • “UART/RS232 Totalizer" on page 362 • “Interpreting UART/RS232 Lister Data" on page 363 • “Searching for UART/RS232 Data in the Lister" on page 363 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Expand the horizontal scale to allow the data to display. • An unknown (undefined) bus is shown in red. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
When an overflow condition occurs, the counter displays OVERFLOW. The counters can be reset to zero by pressing the Reset UART Counters softkey in the UART/RS232 Settings Menu. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
2 In the Search Menu, press the Search softkey; then, turn the Entry knob to select the serial slot (Serial 1 or Serial 2) on which the UART/RS232 signals are being decoded. 3 In the Search Menu, press Search; then, select from these options: Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 364
Rx or Tx Any Error — Finds any error. • For more information on searching data, see “Searching Lister Data" page 114. For more information on using the [Navigate] key and controls, see “Navigating the Time Base" on page 56. Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 365
Base measurement, channel, vernier, Addresses softkey, BIN file format, channel, vertical sensitivity, Agilent IO Libraries Suite, binary data (.bin), characteristics, aliasing, binary data file examples, choosing values, aliasing, FFT, binary data in MATLAB, cleaning, Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 366
EEPROM data read, I2C trigger, flash drive, default setup, 27, either edge trigger, Flat top FFT window, Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 367
Japanese front panel overlays, high-frequency noise rejection, Japanese user interface and Quick mask files, recall, high-resolution mode, 173, Help, mask test, trigger output, 223, holdoff, mask testing, Horiz key, 34, 45, 50, 52, Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 371
Width - measurement, Width + measurement, Window, FFT, X at Max Y measurement, X at Max Y on FFT, X at Min Y measurement, X at Min Y on FFT, XY mode, 49, Z-axis blanking, Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...
Page 372
Index Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide...