27
:SBUS<n> Commands
:SBUS<n>:CAN:SOURce
Command Syntax
:SBUS<n>:CAN:SOURce <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :SBUS<n>:CAN:SOURce command sets the source for the CAN signal.
Query Syntax
:SBUS<n>:CAN:SOURce?
The :SBUS<n>:CAN:SOURce? query returns the current source for the CAN
signal.
Return Format
<source><NL>