Cable Connection; Lan Cable Connection (Twist Pair Cable Compatible With Category 5) (For Operation Management) - Fujitsu Eternus2000 Manual

Disk storage system
Hide thumbs Also See for Eternus2000:
Table of Contents

Advertisement

4.2 Cable Connection

4.2
Cable Connection
Various cables now need to be connected.
4.2.1
LAN Cable Connection (Twist Pair Cable Compatible with Category 5)
(for Operation Management)
This ETERNUS2000 must be connected to a LAN to perform settings or maintenance operations, for
ETERNUSmgr to be used to monitor the device status, or when operating with remote support.
Two 5m LAN cables are supplied with the ETERNUS2000.
IMPORTANT
62
To help with cable management and prevent incorrect connections,
Point
attach labels to the cables and make a note of connection origins and
destinations.
• The ETERNUS2000 has two LAN ports (10BASE-T/100BASE-TX,
MNT port and RMT port) for each controller.
- For device management via setting/maintenance program or
ETERNUSmgr, use MNT port.
- For remote support operation, use MNT port or RMT port. For
remote support on a different network to the customer network,
use the RMT port as the remote support port. For remote support
over the customer network, only the MNT port need be used.
- Operation using only the RMT port without the MNT port is not
allowed.
• The ETERNUS2000 LAN ports operate by default in Auto-Negotia-
tion mode, which recognizes 10BASE-T/100BASE-TX, and Full
duplex / Half duplex automatically.
- When connecting networking equipment such as hubs and rout-
ers, check the specifications and settings of the equipment to be
connected.
- When the LAN ports of the device to be connected operate in
Auto-Negotiation mode, the communication mode is set by the
specified algorithm.
- When the device cannot be recognized correctly, set both devices
to be connected in Fix mode.
• When hub has Spanning Tree Protocol (STP) function and it is
enabled, connection to the ETERNUS2000 may fail. If failed, disable
the STP function.
- When STP function is not necessary for network configuration,
disable the function for hub.
- When STP function is necessary for network configuration, dis-
able the function for the connected port of hub.