Standard Operations; Power On Control - Fujitsu Eternus2000 Manual

Disk storage system
Hide thumbs Also See for Eternus2000:
Table of Contents

Advertisement

2.2

Standard Operations

This section explains how to turn the device on and off, and how to attach and remove the front cover.
2.2.1

Power ON Control

This section describes the procedure to turn the power on.
IMPORTANT
Procedure
1
Press the power switch ( ) of the controller enclosure.
Controller enclosure POWER LED turns on.
2
After a few minutes, check that controller enclosure's READY LED is lit up.
P3AM-2512-03EN
ETERNUS2000 disk storage system User Guide
• After turning the power on, it takes about 4 minutes for the device to
become READY (i.e. the READY LED turns on). If an error is
detected during the initial power-on diagnostic phase, a longer time
(up to ten minutes) may be required before the READY LED turns on.
• Before turning the server on, check that the device, Fibre Channel
switch, and Fibre Channel hub are all READY. If the server is turned
on while any of these devices are not READY, the server will not be
able to recognize the device.
Note:
When drive enclosures are installed, the power turns on automatically.
Power switch
Copyright 2009 FUJITSU LIMITED
Drive enclosure 9
Drive enclosure 8
Drive enclosure 7
Drive enclosure 6
Drive enclosure 5
Drive enclosure 4
Drive enclosure 3
Drive enclosure 2
Drive enclosure 1
Controller enclosure
Chapter 2 Hardware