Switch Test Parameters - Qlogic SANbox 5800V Series Interface Manual

Stackable fibre channel switch
Hide thumbs Also See for SANbox 5800V Series:
Table of Contents

Advertisement

A
Notes
Table 14-45
LoopCount
FrameSize
DataPattern
StopOnError
LoopForever
To cancel a switch test in progress, enter the
To display the status of a recent switch test or switch test in progress, enter the
Test Status
Examples
The following example performs an offline internal test on a switch:
SANbox #> admin start
SANbox (admin) #>set switch state diagnostics
SANbox (admin) #> test switch offline internal
A list of attributes with formatting and current values will follow. Enter a new
value or simply press the ENTER key to accept the default value. If you wish to
terminate this process before reaching the end of the list press 'q' or 'Q' and the
ENTER key to do so.
LoopCount
FrameSize
DataPattern
StopOnError
LoopForever
Do you want to start the test? (y/n) [n] y
59263-02 A
describes the switch test parameters.
Table 14-45. Switch Test Parameters
Parameter
Switch command.
(decimal value, 1-4294967295)
(decimal value, 40-2148)
(32-bit hex value or 'Default') [Default]
(True / False)
(True / False)
14 – Command Reference
Description
Number of frames sent: 1–4294967295.
The default is 100.
Number of bytes in each test frame:
40–2148. The default is 256.
32-bit hexadecimal test value, or default,
which defines random data
Stops the test when an error occurs (True).
Otherwise, the test continues to comple-
tion.
Restarts the test after completion and con-
tinues until you cancel it (True). Otherwise,
the test ends normally after completion.
Test Cancel
Switch command.
[100
]
[256
]
[True
]
[False
]
Command Listing
14-201

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents