Qlogic SANbox 5800V Series Interface Manual page 278

Stackable fibre channel switch
Hide thumbs Also See for SANbox 5800V Series:
Table of Contents

Advertisement

14 – Command Reference
Command Listing
Notes
The switch will down a port if an alarm condition is not cleared within three
consecutive sampling windows (by default, 30 seconds). Reset the port to bring it
back online. An alarm is cleared when the threshold monitoring detects that the
error rate has fallen below the falling trigger.
Examples
The following is an example of the Set Config Threshold command:
SANbox #> admin start
SANbox
SANbox (admin-config) #> set config threshold
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
ThresholdMonitoringEnabled
CRCErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
DecodeErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
ISLMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LoginMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LogoutMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LOSMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
Finished configuring attributes.
This configuration must be saved (see config save command) and activated (see
config activate command) before it can take effect.
To discard this configuration use the config cancel command.
14-98
(admin) #> config edit
(True / False)
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
(decimal value, 1-1000 sec) [10
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
(decimal value, 1-1000 sec) [10
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
(decimal value, 1-1000 sec) [10
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
(decimal value, 1-1000 sec) [10
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
(decimal value, 1-1000 sec) [10
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
(decimal value, 1-1000 sec) [10
S
[False
]
[True
]
[25
]
[1
]
]
[True
]
[25
]
[0
]
]
[True
]
[2
]
[0
]
]
[True
]
[5
]
[1
]
]
[True
]
[5
]
[1
]
]
[True
]
[100
]
[5
]
]