To Save The Test Mask - Rigol DS6000 Series User Manual

Ds6000 series digital oscilloscope
Hide thumbs Also See for DS6000 Series:
Table of Contents

Advertisement

RIGOL
Press Stop On Outp to select "ON" or "OFF".
ON: when failed waveforms are detected, the oscilloscope will stop the test and
enter the "STOP" state. At this point, the results of the test remain the same
with the display on the screen (if display is turned on) and the [Trig
Out/Calibration] (if enabled) connector at the rear panel only outputs one
pulse.
OFF: the oscilloscope will continue with the test even though failed waveforms
are detected. The test results on the screen will update continuously and the
[Trig Out/Calibration] connector at the rear panel will output a pulse each
time a failed waveform is detected.
Press Output to select "Fail" or "Fail+
Fail: when failed waveforms are detected, there are display and output but the
beeper does not sound.
Fail+
: when failed waveforms are detected, there are display and output and
the beeper sounds (not related to the on/off state of the sound).
Press AuxOutput to quickly turn "ON" or "OFF" the measurement output from the
[Trig Out/Calibration] connector at the rear panel. You can also press UTIL 
AuxOutput and select "PassFail" to set this output.

To Save the Test Mask

Users can save the current test mask to the Flash memory inside the instrument or
external USB storage device. The file format of the test mask file is "*.pf". The
internal memory can store at most 10 test mask file (LocalPF.pf).
Press Save to enter file saving interface. Please refer to the relative description in
"Store and Recall" to save the test mask file to the internal or external memory.
9-4
".
9 Pass/Fail Test
DS6000 User's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds6104Ds6102Ds6064Ds6062

Table of Contents