5 To Trigger the Oscilloscope
Slope Trigger
Trigger on the positive or negative slope with specified time.
Trigger Type:
Press Type to select "Slope". At this point, the trigger setting information as shown
in the figure below is displayed at the upper right corner of the screen.
Source Selection:
Press Source to select CH1-CH4 as the Trigger Source. The current trigger source
is displayed at the upper right corner of the screen.
Note: select channel with signal input as trigger source to obtain stable trigger.
Slope Condition:
Press When to select the desired slope condition.
: trigger when the positive slope time of the input signal is greater than
the specified Time.
: trigger when the positive slope time of the input signal is lower than the
specified Time.
: trigger when the positive slope time of the input signal is greater than
the specified Lower Limit of Time and lower than the specified Upper Limit of
Time.
: trigger when the negative slope time of the input signal is greater than
the specified Time.
: trigger when the negative slope time of the input signal is lower than
the specified Time.
: trigger when the negative slope time of the input signal is greater than
the specified Lower Limit of Time and lower than the specified Upper Limit of
Time.
DS6000 User's Guide
RIGOL
5-11