Sign In
Upload
Manuals
Brands
Rigol Manuals
Test Equipment
DS6102
Rigol DS6102 Manuals
Manuals and User Guides for Rigol DS6102. We have
4
Rigol DS6102 manuals available for free PDF download: User Manual, Performance Verification Manual, Declassification Manual
Rigol DS6102 User Manual (298 pages)
Digital Oscilloscope
Brand:
Rigol
| Category:
Test Equipment
| Size: 3 MB
Table of Contents
Guaranty and Declaration
3
Safety Requirement
4
General Safety Summary
4
Safety Notices and Symbols
7
Allgemeine Sicherheits Informationen
8
Sicherheits Begriffe und Symbole
11
Measurement Category
12
Ventilation Requirement
13
Working Environment
14
Pollution Degree
15
Pollution Degree Definitions
15
Care and Cleaning
16
Environmental Considerations
17
DS6000 Series Overview
19
Document Overview
21
Table of Contents
24
1 Quick Start
31
General Inspection
32
Appearance and Dimensions
33
Preparations for Use
34
To Remove the Cover
34
To Adjust the Supporting Legs
35
To Connect to AC Power Supply
36
To Use the Battery
37
Power-On Inspection
38
To Connect the Probe
39
Function Inspection
42
Probe Compensation
44
Front Panel Overview
45
Rear Panel Overview
47
Front Panel Function Overview
49
Vertical
49
Horizontal
51
Trigger
52
Run/Stop
52
Single
53
Auto
53
Multifunction Knob
54
Navigation Knob
54
Function Keys
55
Record
55
Meas
56
Clear
56
Print
56
User Interface
57
Trigger Type
59
Security Lock
63
Desk Mount Instrument Arm
64
Built-In Help System
65
2 To Set the Vertical System
67
To Enable the Channel
68
Channel Coupling
69
Bandwidth Limit
70
Probe
71
Input Impedance
75
Waveform Invert
75
Vertical Scale
76
Vertical Position
77
Vertical Expansion
78
Amplitude Unit
78
Channel Label
79
Delay Calibration
80
3 To Set the Horizontal System
81
Delayed Sweep
82
Time Base Mode
84
Y-T Mode
84
X-Y Mode
85
Roll Mode
88
Horizontal Scale
89
Horizontal Position
89
Horizontal Reference
91
4 To Set the Sample System
93
Acquisition Mode
94
Normal
94
Average
94
Peak Detect
96
High Resolution
96
Sample Mode
97
Real-Time Sample
97
Equivalent Sample
97
Sample Rate
98
Memory Depth
100
Anti-Aliasing
101
5 To Trigger the Oscilloscope
103
Trigger Source
104
Trigger Mode
105
Trigger Coupling
107
Trigger Holdoff
108
Trigger Type
109
Edge Trigger
110
Pulse Trigger
112
Slope Trigger
114
Time Setting
115
Vertical Window
115
Video Trigger
117
Pattern Trigger
119
RS232 Trigger
121
I2C Trigger
123
SPI Trigger
126
CAN Trigger
128
Flexray Trigger
131
USB Trigger
133
Trigger Output Connector
135
6 To Make Measurements
137
Math Operation
138
Addition
138
Subtraction
139
Multiplication
139
Division
141
Fft
142
Logic Operation
145
Advanced Operation
147
Auto Measurement
150
Quick Measurement after Auto
151
One-Key Measurement
152
Frequency Counter Measurement
159
Measurement Setting
160
To Clear the Measurement
162
All Measurement
163
Statistic Function
164
Measurement History
164
Cursor Measurement
165
Manual Mode
167
Track Mode
171
Auto Mode
175
X-Y Mode
176
7 Protocol Decoding
179
Parallel Decoding
180
RS232 Decoding (Option)
183
I2C Decoding (Option)
188
SPI Decoding (Option)
191
CAN Decoding (Option)
195
Flexray Decoding (Option)
199
8 Reference Waveform
203
To Enable REF Function
204
To Set the Color
205
To Select REF Source
206
To Save to Internal Memory
206
To Adjust REF Waveform Display
206
To Export to Internal or External Memory
207
To Import from Internal or External Memory
207
9 Pass/Fail Test
209
To Enable Pass/Fail Test Function
210
To Select Source
211
Mask Range
211
Test and Output
212
To Save the Test Mask
213
To Load the Test Mask
213
10 Waveform Recording
215
Record Constant on
218
Waveform Playback
219
Waveform Analysis
221
Analysis Based on Trace
224
Analysis Based on Pass/Fail Mask
225
11 Display Control
227
To Select the Display Type
228
To Set the Persistence Time
229
To Set the Waveform Brightness
231
To Set the Screen Grid
231
To Set the Grid Brightness
231
To Set the Menu Display
231
12 Store and Recall
233
Storage System
234
Storage Type
235
Internal Store and Recall
237
External Store and Recall
240
Disk Management
242
To Select File Type
243
To Create a New File or Folder
244
To Delete a File or Folder
247
To Rename a File or Folder
247
To Clear the Local Memory
248
Factory
249
13 System Function Setting
257
Remote Interface Configuration
258
LAN Setting
258
USB Device
262
To Set the GPIB Address
262
System-Related
263
Sound
263
Language
263
System Information
263
Power-Off Recall
264
System Time
264
Self-Calibration Information
265
Screen
265
Error Information
266
Self-Calibration
266
Power Status
267
External Trigger Impedance
267
Aux Output
267
Reference Clock
268
Option Management
269
To Print the Waveform
271
To Connect the Print Device
271
Normal Print
272
Pictbridge Print
273
14 Remote Control
275
Remote Control Via USB
276
Remote Control Via LAN
280
Remote Control Via GPIB
282
15 Troubleshooting
285
16 Specifications
287
General Specifications
294
Calibration Interval
294
17 Appendix
295
Appendix A: Accessories and Options
295
Appendix B: Warranty
296
Index
297
Advertisement
Rigol DS6102 User Manual (280 pages)
DS6000 Series Digital Oscilloscope
Brand:
Rigol
| Category:
Test Equipment
| Size: 5 MB
Table of Contents
Guaranty and Declaration
3
Safety Requirement
4
General Safety Summary
4
Safety Terms and Symbols
6
Measurement Category
7
Ventilation Requirement
8
Working Environment
9
Pollution Degree
10
Pollution Degree Definitions
10
General Care and Cleaning
11
Environmental Considerations
12
DS6000 Series Overview
13
Document Overview
15
Table of Contents
17
1 Quick Start
23
General Inspection
24
Appearance and Dimensions
25
To Prepare the Oscilloscope for Use
26
To Remove the Cover
26
To Adjust the Supporting Legs
27
To Connect to AC Power Supply
28
To Use the Battery
29
Power-On Inspection
30
To Connect the Probe
31
Function Inspection
32
Probe Compensation
34
Front Panel Overview
35
Rear Panel Overview
36
Front Panel Function Overview
38
Vertical
38
Horizontal
40
Trigger
41
Run/Stop
41
Single
42
Auto
42
Knob
43
Navigation Knob
43
Menu
44
Record
44
Meas
45
Clear
45
Print
45
User Interface
46
To Use the Security Lock
51
To Use the Desk Mount Instrument Arm
52
To Use the Rack Mount Kit
53
Kit Parts List
53
Installation Tool
54
Installation Space
54
Installation Procedures
55
To Use the Built-In Help System
58
2 To Set the Vertical System
59
To Enable the Channel
60
Channel Coupling
61
Bandwidth Limit
62
Probe
62
Input Impedance
65
Waveform Invert
66
Vertical Scale
66
Vertical Expansion
67
Amplitude Unit
67
Channel Label
68
Delay Calibration
69
3 To Set the Horizontal System
71
Delayed Sweep
72
Time Base Mode
74
Y-T Mode
74
X-Y Mode
75
Roll Mode
78
Horizontal Scale
79
Horizontal Reference
80
4 To Set the Sample System
83
Acquisition Mode
84
Normal
84
Average
84
Peak Detect
86
High Resolution
86
Sample Mode
87
Real-Time Sample
87
Equivalent Sample
87
Sample Rate
88
Memory Depth
90
Antialiasing
91
5 To Trigger the Oscilloscope
93
Trigger Source
94
Trigger Mode
95
Trigger Coupling
97
Trigger Holdoff
98
Trigger Type
99
Edge Trigger
100
Pulse Trigger
101
Pulse Condition
101
Pulse Width Setting
102
Slope Trigger
103
Slope Condition
103
Time Setting
104
Vertical Window
104
Video Trigger
106
Video Polarity
106
Video Standard
106
Pattern Trigger
108
Pattern Setting
108
RS232 Trigger
110
I2C Trigger
112
SPI Trigger
115
CAN Trigger
117
Flexray Trigger
120
USB Trigger
122
Trigger Ouput Connector
124
6 To Make Measurements
125
Math Operation
126
Addition
126
Subtraction
127
Multiplication
127
Division
128
Fft
129
Logic Operation
132
Advanced Operation
134
Auto Measurement
137
Quick Measurement after Auto
138
One-Key Measurement of 24 Parameters
139
Other Parameters
143
Frequency Counter Measurement
144
Measurement Setting
145
Clear the Measurement
147
All Measurement
148
Statistic Function
149
Measurement History
150
Cursor Measurement
151
Manual Mode
152
Track Mode
155
Auto Mode
158
7 Protocol Decoding
159
Parallel Decoding
160
RS232 Decoding (Option)
163
I2C Decoding (Option)
168
SPI Decoding (Option)
171
CAN Decoding (Option)
174
Flexray Decoding (Option)
177
8 Reference Waveform
181
To Enable REF Function
182
To Set the Color
183
To Select REF Source
184
To Save to Internal Memory
184
To Adjust REF Waveform Display
184
To Export to Internal or External Memory
185
To Import from Internal or External Memory
185
9 Pass/Fail Test
187
To Enable Pass/Fail Test Function
188
To Select Source
189
Mask Range
189
Test and Output
189
To Save the Test Mask
190
To Load the Test Mask
191
10 Waveform Recording
193
Waveform Playback
196
Waveform Analysis
198
Analysis Based on Trace
201
Analysis Based on Pass/Fail Mask
202
11 Display Control
205
To Select the Display Type
206
To Set the Persistence Time
207
To Set the Waveform Brightness
209
To Set the Screen Grid
209
To Set the Grid Brightness
209
To Set the Menu Display
209
12 Store and Recall
211
Storage System
212
Storage Type
213
Internal Store and Recall
215
External Store and Recall
217
Disk Management
219
To Select File Type
220
To Create a New File or Folder
221
To Delete a File or Folder
224
To Rename a File or Folder
224
To Clear the Local Memory
225
Factory
226
13 System Function Setting
233
Remote Interface Configuration
234
LAN Setting
234
Network Status
234
USB Device
238
To Set the GPIB Address
238
System-Related
239
Sound
239
Language
239
System Information
239
Power-Off Recall
240
System Time
241
Self-Calibration Information
242
Screen
243
Error Information
244
Self-Calibration
245
Power Status
246
External Trigger Impedance
246
Aux Output
247
Reference Clock
248
Option Management
249
To Print the Waveform
250
To Connect the Print Device
250
Normal Print
251
Pictbridge Print
252
14 Remote Control
255
Remote Control Via USB
256
Remote Control Via LAN
260
Remote Control Via GPIB
263
15 Troubleshooting
265
16 Specifications
267
General Specifications
273
Calibration Interval
273
17 Appendix
275
Appendix A: Options and Accessories
275
Appendix B: Warranty
276
Appendix C: any Question or Comment
277
Index
279
Rigol DS6102 Performance Verification Manual (43 pages)
Digital Oscilloscope
Brand:
Rigol
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Guaranty and Declaration
3
General Safety Summary
4
Safety Terms and Symbols
6
Allgemeine Sicherheits Informationen
7
Sicherheits Begriffe und Symbole
9
Table of Contents
10
Document Overview
12
Chapter 1 Overview
13
Test Preparations
13
Self-Test
13
Self-Calibration
13
Test Result Record
14
Specifications
14
Chapter 2 Performance Verification Test
15
Impedance Test
16
Specification
16
Test Connection Diagram
16
Test Procedures
16
Test Record Form
18
DC Gain Accuracy Test
19
Specification
19
Test Connection Diagram
19
Test Procedures
19
Test Record Form
21
Bandwidth Test
24
Specification
24
Test Connection Diagram
24
Test Procedures
24
Test Record Form
26
Bandwidth Limit Test
27
Specification
27
Test Connection Diagram
27
Test Procedures
27
Test Record Form
30
Time Base Accuracy Test
32
Specification
32
Test Connection Diagram
32
Test Procedures
32
Test Record Form
33
Zero Point Offset Test
34
Specification
34
Test Connection Diagram
34
Test Procedures
34
Test Record Form
36
Appendix Test Record Form
37
Advertisement
Rigol DS6102 Declassification Manual (16 pages)
Digital Oscilloscope
Brand:
Rigol
| Category:
Test Equipment
| Size: 0 MB
Advertisement
Related Products
Rigol DS6000 Series
Rigol DS6104
Rigol DS6064
Rigol DS6062
Rigol DS6062-DEMO
Rigol DS1102D
Rigol DS1052D
Rigol DS1000B Series
Rigol DS1102CD
Rigol DS1062CD
Rigol Categories
Test Equipment
Measuring Instruments
Portable Generator
Power Supply
Inverter
More Rigol Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL