To do...
Enter system view
Enter Ethernet port view
Set the interval to perform
statistical analysis on port
traffic

Enabling Giant-Frame Statistics Function

The giant-frame statistics function is used to ensure normal data transmission and to facilitate statistics
and analysis of unusual traffic on the network.
Follow these steps to enable the giant-frame statistics function:
To do...
Enter system view
Enable the giant-frame
statistics function

Disabling Up/Down Log Output on a Port

An Ethernet port has three physical link statuses: Up, Down, and Administratively Down. For status
transition conditions, refer to the description of the display brief interface command in Basic Port
Configuration Command.
When the physical link status of an Ethernet port changes between Up and Down or Up and
Administratively Down, the switch will generate Up/Down log and send the log information to the
terminal automatically by default. If the status of Ethernet ports in a network changes frequently, large
amount of log information may be sent to the terminal, which consumes more network resources.
Additionally, too frequent log information is not convenient for you to view.
You can limit the amount of the log information sent to the terminal by disabling the Up/Down log output
function on some Ethernet ports selectively. For information about log output settings, refer to the
Information Center module.
Disable Up/Down log output on a port
Follow these steps to disable UP/Down log output on a port:
To do...
Enter system view
Enter Ethernet port view
Disable a port from generating
UP/Down log
Use the command...
system-view
interface interface-type
interface-number
flow-interval interval
Use the command...
system-view
giant-frame statistics
enable
Use the command...
system-view
interface interface-type
interface-number
undo enable log updown
1-8
Remarks
Optional
By default, this interval is 300
seconds.
Remarks
Required
By default, the giant-frame statistics
function is not enabled.
Remarks
Required
By default, UP/Down log output
is enabled.