3Com 5500-EI PWR Install Manual page 41

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

To do...
Create a local user and enter
local user view
Set the authentication
password for the local user
Specify the service type for
VTY users
Quit to system view
Enter one or more VTY user
interface views
Configure to authenticate
users locally or remotely
Configure the command level
available to users logging in
to the user interface
Configure the supported
protocol
Make terminal services
available
Set the maximum number of
lines the screen can contain
Set history command buffer
size
Set the timeout time for the
user interface
Use the command...
local-user user-name
password { simple | cipher }
password
service-type telnet [ level
level ]
quit
user-interface vty
first-number [ last-number ]
authentication-mode
scheme [ command-
authorization ]
user privilege level level
protocol inbound { all | ssh
| telnet }
shell
screen-length screen-length
history-command max-size
value
idle-timeout minutes
[ seconds ]
3-8
Remarks
No local user exists by default.
Required
Required
Required
The specified AAA scheme
determines whether to authenticate
users locally or remotely.
Users are authenticated locally by
default.
Optional
By default, commands of level 0 are
available to users logging in to the
VTY user interfaces.
Optional
Both Telnet protocol and SSH
protocol are supported by default.
Optional
Terminal services are available in
all use interfaces by default.
Optional
By default, the screen can contain
up to 24 lines.
You can use the screen-length 0
command to disable the function to
display information in pages.
Optional
The default history command buffer
size is 10. That is, a history
command buffer can store up to 10
commands by default.
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a user
interface is terminated if no
operation is performed in the user
interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.