Copyright © 2010, Juniper Networks, Inc.
Table 141: Link Management Protocol Configuration Details (continued)
Task
Configure a Lmp Control
Channel.
Your Action
1.
Click Lmp Control Channel next to peer.
2.
Click Add new entry next to Lmp Control Channel.
3.
In the Name box, enter the peer name.
4.
In the Comment box, enter the comment.
5.
In the Remote Address box, enter the remote IP address for
the Link Management Protocol (LMP) control channel
interface.
6.
Click Lmp Protocol next to peer.
7.
In the Comment box, enter the comment.
8.
From the Hello Interval list, select how often the router sends
Link Management Protocol (LMP) hello packets.
Range: 150 through 21845
Default: 150 milliseconds
9.
From the Hello Dead Interval list, select how long the Link
Management Protocol (LMP) waits before declaring the
control channel to be dead.
Range: 500 through 300,000
Default: 500 milliseconds (three times the hello interval)
10.
From the Retransmission Interval list, select how often Link
Management Protocol (LMP) sends Config and LinkSummary
messages on the LMP control channel.
Range: 500 through 300,000
Default: 500 milliseconds
11.
From the Retry Limit list, select the maximum number of
times messages are sent without receiving an
acknowledgment.
Range: 3 through 1000
Default: 3
12.
Select Passive check box to specify the router to not
configure the Link Management Protocol (LMP) control
channels, but to wait for the remote peer to configure the
LMP control channels.
13.
Click Te-Link next to peer.
14.
Click Add new entry next to Te-Link.
15.
In the dialog box, enter the name of the te-link to be
associated with this peer.
Chapter 20: Configuring Protocols