Table 3-2
TFTP Configuration File Parameters (continued)
mdns-config:
Enables or disables Multicast Domain Name System (mDNS) services. 0 disables, 1 (default) enables. mDNS is
typically used on small networks for IP address and name resolution (through UDP port 5353) where a conventional
DNS server is neither used or available.
mdns-service-name:
Specifies an alphanumeric string of up to 64 ASCII characters assigned to this device or service. This name is
persistent and is used to resolve a particular device or service if socket information (such as the IP address) changes
from session to session. Apple mDNS will display this service. The default service name is the printer model and the
LAN Hardware (MAC) address.
mdns-pri-svc:
Specifies the mDNS highest priority service to use for printing.To set this parameter, choose one of the following
printing option numbers:
1: Port 9100 printing
2: IPP port printing
3: The default LPD raw queue
4: The default LPD text queue
5: The default LPD auto queue
6: The default LPD binps (binary postscript) queue
7 through 12: If user-specified LPD queues are defined, corresponds to user-specified LPD queues 5 through 10.
The default selection will depend on the printer, typically port 9100 printing or LPD binps.
ipv4-multicast:
Enables or disables the receipt and transmission of IP version 4 multicast packets by the print server. 0 disables, 1
(default) enables.
NOTE
also be disabled without notification.
idle-timeout:
The number of seconds that an idle print data connection is allowed to remain open. Since the card supports only a
single TCP connection, the idle timeout balances the opportunity of a host to recover or complete a print job against the
ability of other hosts to access the printer. The acceptable values range from 0 to 3600 (1 hour). If "0" is typed, the
timeout mechanism is disabled. The default is 270 seconds.
user-timeout:
An integer (1..3600) that specifies the number of seconds that your Telnet or FTP session can be idle before it will be
automatically disconnected. The default is 900 seconds. 0 disables the timeout.
CAUTION
terminate before any changes can be made.
ews-config:
Enables or disables the print server's embedded Web server to change configuration values: 0 disables, 1 (default)
enables.
32
Chapter 3
TCP/IP Configuration
If this parameter is disabled, other protocols that use multicast protocols, such as mDNS and SLP, may
(or telnet-timeout:)
Small values, such as 1–5, may effectively disable the use of Telnet. A Telnet session may
(or web:)
ENWW

Advertisement

Table of Contents
loading

This manual is also suitable for:

635n

Table of Contents