Executing touch probe cycles

All touch probe cycles are DEF active. This means that the TNC runs
the cycle automatically as soon as the TNC executes the cycle
definition in the program run.
Make sure that at the beginning of the cycle the
compensation data (length, radius) from the calibrated
data or from the last TOOL CALL block are active
(selection via MP7411, see the User's Manual of the
iTNC530, "General User Parameters").
You can also run the Touch Probe Cycles 408 to 419 during
an active basic rotation. Make sure, however, that the
basic rotation angle does not change when you use Cycle
7 DATUM SHIFT with datum tables after the measuring
cycle.
Touch probe cycles with a number greater than 400 position the touch
probe according to a positioning logic:
If the current coordinate of the south pole of the stylus is less than
the coordinate of the clearance height (defined in the cycle), the TNC
retracts the touch probe in the probe axis to the clearance height
and then positions it in the working plane to the first starting
position.
If the current coordinate of the south pole of the stylus is greater
than the coordinate of the clearance height, the TNC first positions
the probe in the working plane to the first starting position and then
moves it immediately to the measuring height in the touch probe
axis.