U
Traversing to clearance height Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternatively PREDEF
U
Default setting for basic rotation Q307
(absolute): If the misalignment is to be measured
against a straight line other than the reference axis,
enter the angle of this reference line. The TNC will
then calculate the difference between the value
measured and the angle of the reference line for the
basic rotation. Input range -360.000 to 360.000
U
Preset number in table Q305: Enter the preset
number in the table in which the TNC is to save the
determined basic rotation. If you enter Q305=0, the
TNC automatically places the determined basic
rotation in the ROT menu of the Manual Operation
mode. Input range 0 to 2999
324
Example: NC blocks
5 TCH PROBE 400 BASIC ROTATION
Q263=+10 ;1ST POINT 1ST AXIS
Q264=+3.5 ;1ST POINT 2ND AXIS
Q265=+25 ;2ND POINT 1ST AXIS
Q266=+8
Q272=2
Q267=+1
Q261=-5
Q320=0
Q260=+20 ;CLEARANCE HEIGHT
Q301=0
Q307=0
Q305=0
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
;2ND POINT 2ND AXIS
;MEASURING AXIS
;TRAVERSE DIRECTION
;MEASURING HEIGHT
;SET-UP CLEARANCE
;MOVE TO CLEARANCE
;PRESET BASIC ROTATION
;NO. IN TABLE
Need help?
Do you have a question about the ITNC 530 - CYCLE PROGRAMMING and is the answer not in the manual?
Questions and answers
Can I change the approach direction when cycle def a stud to avoid obstruction to the right
The provided context does not explicitly mention changing the approach direction to avoid obstruction. However, it describes selecting different axis configurations using the MOD function in the Programming and Editing mode. If modifying the axis configuration allows for adjusting the approach direction, it may be possible. Otherwise, specific cycle parameters should be checked in the programming manual.
This answer is automatically generated