HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING User Manual page 364

Cycle programming
Table of Contents

Advertisement

15.7 DATUM FROM OUTSIDE OF
CIRCLE (Cycle 413, DIN/ISO:
G413)
Cycle run
Touch Probe Cycle 413 finds the center of a circular stud and defines
it as datum. If desired, the TNC can also enter the coordinates into a
datum table or the preset table.
1 Following the positioning logic (see "Executing touch probe
cycles" on page 318), the TNC positions the touch probe to the
probe starting point
1
at rapid traverse (value from MP6150). The
TNC calculates the probe starting points from the data in the cycle
and the safety clearance from MP6140.
2 Then the touch probe moves to the entered measuring height and
probes the first touch point at the probing feed rate (MP6120). The
TNC derives the probing direction automatically from the
programmed starting angle.
3 Then the touch probe moves in a circular arc either at measuring
height or at clearance height to the next starting point
the second touch point.
4 The TNC positions the probe to starting point
point
4
to probe the third and fourth touch points.
5 Finally the TNC returns the touch probe to the clearance height and
processes the determined datum depending on the cycle
parameters Q303 and Q305 (see "Saving the calculated datum"
on page 344) and saves the actual values in the Q parameters
listed below.
6 If desired, the TNC subsequently measures the datum in the touch
probe axis in a separate probing.
Parameter number
Meaning
Q151
Actual value of center in reference axis
Q152
Actual value of center in minor axis
Q153
Actual value of diameter
364
2
and probes
3
and then to starting
Touch Probe Cycles: Automatic Datum Setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Itnc 530 e