4 The TNC automatically measures all three axes successively in the
resolution you defined.
5 The TNC saves the measured values in the following Q
parameters:
Parameter number
Meaning
Q141
Standard deviation measured in the A axis
(–1 if axis was not measured)
Q142
Standard deviation measured in the B axis
(–1 if axis was not measured)
Q143
Standard deviation measured in the C axis
(–1 if axis was not measured)
Q144
Optimized standard deviation in the A axis
(–1 if axis was not optimized)
Q145
Optimized standard deviation in the B axis
(–1 if axis was not optimized)
Q146
Optimized standard deviation in the C axis
(–1 if axis was not optimized)
HEIDENHAIN iTNC 530
467