Programming ISDN PRI resources

Some steps will not be necessary, depending on the service
you are providing.
More detailed information is included under the individual
headings and settings in the Programming and Maintenance
sections.
For complete card and cartridge installation instructions and
safety precautions, see Installation on page 227.
1. Collect the information supplied by your service provider
to support your ISDN package.
2. Ensure that a Combination Fiber 6-port Services
Cartridge, or a Services Cartridge has been installed in the
ICS.
3. Install the DTI cards in the ICS. Refer to Installing the
cartridges on page 231 for information about card
placement. If you are not using DTI cards, determine
which type of card you will preprogram the ICS to use in
each slot.
Tips -
card can be installed off-core on Module 3 or 4 on the Midi
system, or module 7 or 8 on the Maxi system to expand the PRI
capability of your system. This card is only supported on
Profile 1 and 4.
Note: Legacy DTI cards cannot be used off-core. A new DTI
card was released in 2002 that can be used in any position.
4. Disable each card under Maintenance.
5. Select a card type (PRI) in Hardware. See Provisioning
the DTI card for PRI on page 497, for information about
protocol and other settings you must configure.
N0130943 02
For systems running 6.0 or greater software, a DTI
Working with ISDN / 77
Modular ICS 7.1 Installer Guide