556 / Event messages

Significant event messages

The following table lists event messages that are relevant to
Maintenance activities. The time that the message is recorded
is also provided.
Displays
Event message
Evt:210-YYYZ
Evt:211-YYYZ
Evt:220-3546
Evt:221-3546
Evt:222-3546
Evt:255
Evt:260-0302
Evt:261-0302
Evt:263-302
Evt:264-302
Evt:265-302
Evt:267
Evt:268-07
Modular ICS 7.1 Installer Guide
The event message is recorded when...
S4
Loopback test YYY on Trunk Cartridge Z has
started
S4
Loopback test YYY on Trunk Cartridge Z has
stopped
S4
the Sys admin log has been cleared by the DN
(3546 in this case)
S4
the Sys test log has been cleared by the DN (3546
in this case)
S5
the DN (3546 in this case) enters the debugging
facility that is password protected
S9
administered mode is not supported by the cartridge
plugged into the slot
S8
the ICS takes the access line on port 0302 out of
service because no current was detected
S1
the access line on port 0302 is returned to service
after current was detected (see Evt:260)
S8
the ICS takes the E&M line on port 302 out of
service because the far end did not respond to a
disconnect signal
S1
the E&M line on port 302 is returned to service after
the far end finally responded to a disconnect signal
(see Evt:263)
S7
the E&M line on port 302 did not receive an
expected wink signal or delay dial signal from the far
end
S9
a data module has been disconnected
S8
Dialing filter 07 has lost data due to a fault in the
system memory
N0130943 02