Outgoing Name and Number Blocking

When activated, ≤°⁄· blocks the outgoing name and
number on a per call basis. When this feature is used, the call
is flagged to the CO so that the name and number will not be
presented to the person being called.
On analog and BRI trunks, a call blocking digit sequence is
sent to the CO before sending the dialout digits. You can
change this digit in a Norstar programming session and set it
to the digit sequence recognized by the local CO for name and
number blocking.
This programming is done in the main program heading Telco
Features. To program the Name and Number blocking digit,
start with the display showing Telco features.
Note: Step 1 through 3 are only for analog and BRI trunks.
1. Press ≠. The display shows VMsg ctr tel#s.
2. Press ' until the display shows ONN Blocking:.
3. Press ≠. The display shows Tone:None. You can
choose F78, (0-9), *, #.
4. Press CHANGE to enter a new tone dialing Name and
Number blocking digit sequence.
5. Press '. The display shows Pulse:None. You
can choose F78, (0-9), *, #.
6. Press CHANGE to enter a new pulse dialing Name and
Number blocking digit sequence.