Private network: UDP
If your dialing plan will be using Location codes to navigate to
other systems, specify a uniform dialing plan (UDP).
1. At Type:None, press CHANGE until UDP displays.
2. Press '. PrivNetID:1 displays.
3. Press CHANGE, and enter a new private network id.
4. Press '. Loc code:None displays.
5. Press CHANGE and use the dialpad to enter a location code.
Note: This code must be unique to your system.
6. Press '. Priv DN len:3 displays.
7. Press CHANGE to choose a new private DN length. (3-14)
Note: The Private DN length must match the DN lengths
being used by the other systems in the network. This is
what enbloc dialing uses to determine when the
complete number has been dialed.

Public networks

When you identify public DNs on a network, use the Dialing
Rules to define any prefixes that need to be dialed out. The
public network refers to connections to the public switching
network (PSTN).
1. At Public Network, press ≠.
Pub DN lengths displays.
2. Press '. PrivNetID:1 displays.
3. Press ≠. Show prfix: displays.
4. Press ADD and enter a prefix.
Modular ICS 7.1 Installer Guide
N0130943 02